Ultrasonic Pachymeters (Ultrasound Pachymetry)

Ultrasound technology can help probe the human eye without causing damage to this delicate organ, and so its use in ophthalmology is constantly expanding. Ultrasonic pachymeters (or pachometers) allow the surgeon or general ophthalmologist to measure the thickness of the cornea in patients with glaucoma, suspected hypertension or those considering refractive surgery. One primary advantage of an ultrasonic pachymeter is how cost-effective it can be as compared to alternatives such as confocal microscopy. These pachymeters are generally hand-held. In addition to corneal thickness, the customer should seek capabilities like pre-programed formulas for intraocular lenses (IOL) and post-refractive surgery.
Showing 9 of 9 products
  • <<
  • >>
Get quotes for all products
Select up to 5 products from below to compare or request more information.

Featured products

Compare or Get quote for selected.
DGH-555B Pachette 4

DGH-555B Pachette 4

DGH Technology, Inc.

  • Features:
    • Automatic Report Generation Using Wireless Bluetooth® Technology.
    • Ease of use. Turn on power and the Pachette 4 is ready to take measurements.
    • Accuracy & Reproducibility. Proven measurement algorithm yields accurate, reproducible measurements in a fraction of a second.
    • Obtains and stores up to 25 measurements in less than 2 seconds.
    • Personalized Configuration Memory.
    • Durable Portability. Portable, desktop pachymeter encased in a rubber holster with built-in tilt stand. Probe is detachable for easy cleaning and replacement
    • Mapping Mode for obtaining and storing up to 33 actual and biased corneal mapped measurements.
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): 4.1" (104 mm) x 6.3" (160 mm) x 2.2" (56 mm)
  • IOL Formulas: Inquire
  • Biometry Measurement: Measurement Option: Standard Unit Range (µm): 200 to 1100 µm, 95 to 1100 µm (Flap) Accuracy (µm): 5µm Display Resolution (µm): 1 µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare or Get quote for selected.
DGH-55B Pachmate 2

DGH-55B Pachmate 2

DGH Technology, Inc.

  • Features:
    • Automatic Report Generation Using Wireless Bluetooth® Technology.
    • Ease of use. Turn on power and the Pachmate 2 is ready to take measurements.
    • Accuracy & Reproducibility. Proven measurement algorithm yields accurate, reproducible measurements in a fraction of a second.
    • Obtains and stores up to 25 measurements in less than 2 seconds.
    • Personalized Configuration Memory.
    • Durable Portability. Handheld, battery operated, and lightweight.
    • Detachable and Rotatable Probe.
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): 1.6" (41 mm) x 7.1" (181 mm) x 0.9" (23 mm)
  • IOL Formulas: Inquire
  • Biometry Measurement: Measurement Option: Standard Unit Range (µm): 200 to 1100 µm Accuracy (µm): 5µm Display Resolution (µm): 1 µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare or Get quote for selected.
  • Features:
    • Three-in-One unit of B-scan, biometer, and pachymeter
    • High quality B-scan images (only for the US-4000)
    • Fast biometry and accurate pachymetry
    • No PC required
    • Built-in thermal printer
    • Tiltable 8.4-inch XGA color LCD for user-friendly operability
    • USB and LAN interfaces for easy data storage
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Inquire
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare or Get quote for selected.
Pocket II One Touch Ultrasound Pachymeter
  • Features: Essential in predicting glaucoma progression and helping patients’ management, this pachymeter also offers a wide range of applications from measurement of the central Corneal Thickness to corneal mapping for refractive surgery.

    Main characteristics:
    • Fast and precise (+/- 5 microns)
    • Hand-held pachymeter
    • Corneal maps included
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): 8" X 4" x 2"
    Weight: 460 gr (16 oz)
  • IOL Formulas: This feature only applicable for units with built-in A-scan capability
  • Biometry Measurement: Precision with one touch
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare for selected.
MD-1000P Pachymeter

MD-1000P Pachymeter

MEDA CO., LTD.

  • Features: Multiple Corneal Maps with Graphical Display
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Biometry Accuracy: ≤±5µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
  • Features:
    • Automatic and manual gain control modes
    • Immersion Mode measurement
    • Live waveform display
    • Multi-modes measurements
    • Eight groups of measurements to calculate IOL.
    • Portable and sleek.
    • Stores up to 25 measurements by cornea location
    • Build-in thermal printer
      A-Biometer:
    • Gain ≥90dB
    • Gain changeable for users: 0-32dB
    • Accuracy: ≤0.06mm
    • Measure Range: 15-39mm
    • Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
    • Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
      Pachymeter:
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
  • Biometry Measurement: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
ODM-1000P Pachymeter

ODM-1000P Pachymeter

MEDA CO., LTD.

  • Features:
    • Stores up to 25 measurements by cornea location
    • Central and Peripheral cornea map
    • Build-in thermal printer
    • Accurate and Reliable
    • Portable and sleek
      Pachymeter
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Inquire
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
Corneo-Gage™ Plus

Corneo-Gage™ Plus

Sonogage, Inc.

  • Features:
    • Completely Portable-move it from lane to lane, office to office
    • No foot pedal, no power cord
    • Battery level indicator
    • Easy To Use-ergonomic probe with continuous read mode
    • Provides Repeatable Readings of the Highest Accuracy
    • Measures the corneal epithelium- optional mode
    • Exclusive 50 MHz solid state transducer
    • Each individual reading is the average of 1000 ultrasonic echoes
    • Individual readings are not averaged-false high values cannot be obtained
    • Automatic calibration verification
    • Built-in dot matrix printer available
    • Built-in IOP correction chart for glaucoma and hypertension patients-optional
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Built-in IOP correction chart for glaucoma and hypertension patients
  • Biometry Measurement: accurate reproducible corneal thickness measurements
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags