Company | CenterVue | CenterVue | CenterVue | CenterVue | CenterVue |
Item | Compass Fundus Automated Perimetry | DRS Digital Retinography System | Eidon - True Color Confocal Scanner | Eidon AF with Autofluorescence Capability | MAIA Macular Integrity Assessment System |
Citations | | | | | |
Price | Inquire | Inquire | Inquire | Inquire | Inquire |
Description | Compass is the first Fundus Automated Perimeter on the market which combines Visual Field measurement to TrueColor Confocal Imaging of the optic disc and RNFL, a big evolution in clinical glaucoma management. This structure-function correlation and | The DRS is the new frontier of non-mydriatic, digital retinal imaging. Thanks to its fully automated operation, DRS requires minimal operator training. Its compact, ergonomic design and low power flash help ensure patient comfort. DRS is conceived to | EIDON is the first system to combine the advantages of SLO with the fidelity of true color imaging, setting new performance standards in retinal imaging. EIDON provides unsurpassed image quality, 60 degree field in a single exposure, a unique, live | Eidon AF, with Autofluorescence capability, is the natural evolution of Eidon TrueColor Confocal Scanner. 60° Autofluorescence images for the assessment of the Retinal Pigment Epithelium (RPE) are now available, integrated in Eidon technology. Ease | Inquire |
Features |
- Extreme ease of use: patient auto-sensing, auto-alignment, auto-focus
- Auto flash adjustment, auto-capture
- Compact & clean design
- High quality images
- Minimal training required
- No additional PC required
- Touch-screen operation
- Internet-native
| - Extreme ease of use: patient auto-sensing, auto-alignment, auto-focus, auto flash adjustment, auto-capture
- Compact & clean design
- Short exam time: capture both eyes in 1 min (single field)
- High quality images
- Minimal training required
- No additional PC required
- Touch-screen operation
- View images from any PC or tablet
- Wi-Fi and Ethernet connectivity
- Cloud backup available
- Export to USB and remote folder (for import into EMR), DICOM, JPG, PDF
|
- True color, Red Free and infrared confocal images
- Super-high resolution and contrast
- Capability to image through cataract and media opacities
- Dilation-free operation (minimum pupil 2.5 mm)
- Wide Field imaging (60° in single exposure and up to 150° with Mosaic function)
- Optimal exposure of the optic disc
- Exam time less than 1’ per eye (single field)
- From Fully automated to Fully manual mode
- User friendly software interface
|
- Includes all features and functionalities of EIDON technology, adding auto-fluorescence imaging capabilities
- Provides confocality based on scanning line
- Presents the highest pixel resolution (14 MP sensor) for a confocal system
- Captures 60° autofluorescence image with a single flash of light
- Mosaic function provides Wide field up to 110° autofluorescence images
- Operates in fully automatic or manual mode
| - Simple to use, patients can be tested in less than 3 minutes per eye
- By comparing macular indexes in patients with and without retinal pathologies, MAIA is very effective at measuring functional changes due to disease and to treatment
- Helps monitoring the course of retinal diseases and the efficacy of treatment
- Effectively combines a linear SLO system and a fundus controlled perimetric exam, providing clear and detailed retinal images
- New Eye Tracker Alarm for the MAIA - The new MAIA software version 1.5.3 includes the innovative “Eye Tracker Alarm,” a feature that advises the operator when the patient is not properly following the MAIA test. This feature reduces even more the operator’s involvement during screening
|
Weight (lbs) | Inquire | 42 lbs (19 Kg) | Inquire | Inquire | 50.7 lbs (23 kg) |
Interface | Tablet multi-touch screen | Touch-screen | Tablet based | Inquire | Touch screen |
Resolution | 17 microns
Sensor: 5 Mpixel (2592x1944) | Inquire | 60 pixel/deg | 60 pixels/deg
Sensor Resolution: 14 Mpixel (4608x3288) | 1024 x 1024 pixel |
Pupil Diameter | 3 mm (minimum) | Inquire | Inquire | Inquire | Inquire |
Working Distance | 28 mm | 37 mm | 28 mm | 28 mm | 33 mm |
Light Source | Infrared (825-870 nm) and white LED (440-650 nm) | Inquire | Inquire | Near infrared (825-870 nm), blue (440-475 nm) and white (440-650 nm) | Inquire |
Field Angle/Angle of View | 60° (diameter) | Inquire | Inquire | Inquire | Inquire |
Monitor Size | Inquire | 10.4” touch-screen color display | Tablet operated, with 10.1” multi-touch, color display | Inquire | Inquire |
Fixation Targets | Inquire | 7 internal LEDs | Inquire | Inquire | Inquire |
Dimensions | Inquire | 58 x 55 x 33 cm (23’ x 22’ x 13’) | 620 mm x 590 mm x 360 mm | Inquire | 348 x 580 x 600 mm (13.7 x 22.8 x 23.6 in) |
Image Type | Color, infrared, red-free | Inquire | color, infrared, red-free | Color, IR, red-free, autofluorescence | Inquire |
Get quote | Inquire | Inquire | Inquire | Inquire | Inquire |