Contrast Sensitivity Tests

CompanyPrecision Vision®Precision Vision®Precision Vision®Precision Vision®Precision Vision®
ItemPelli-Robson SLOAN Letter Contrast ChartColenbrander Reading, Intermediate and Computer Chart (2 card set)Complete Rabin Contrast Sensitivity SetLow Contrast and Mixed Contrast Eye ChartsTumbling "E" Low Contrast Flip Book
PriceInquireInquireInquireInquireInquire
DescriptionDesigned by DG Pelli, JG Robson and A J Wilkins, because they see contrast sensitivity as a realistic assessment of how well the patient sees large faint objects.

The chart follows the luminance, font, and letter spacing recommendations of the

Designed by: Dr. August Colenbrander

Conventional, high-contrast letter chart acuity captures only one aspect of visual performance. Low contrast acuity is equally important for activities of daily living, since most everyday objects have less than

Test Includes

CAT. NO. 2126 Rabin Contrast Sensitivity Test CAT. NO. 2147 Glare Filter CAT. NO. 2148 Low Photopic Filter CAT. NO. 914 Small Illuminator Cabinet CAT. NO. 915 Adjustable Base

Precision Vision offers a variety of Low Contrast and Mixed Contrast Eye Charts for testing Contrast Sensitivity. Notations for testing at Near Vision, 1 meter, 2 meters, 2.5 meters, 3 meters, 4 meters and Multi-distance. Products range from Flip This flip book is great for vision studies and research world wide. The Tumbling "E" vision chart uses only one optotype for testing. Patients not familiar with the Roman alphabet simply have to gesture or sign which direction they see the "E" facing
Features
  • Features Traditional Sloan Optotypes
  • For use at 40 in (1m)
  • Includes two charts and two scoring pads
  • Illumination of 85 cd/m² is key to good results
  • Calibrated for 40 cm (16 in), 63 cm (25 in), 100 cm (40 in)
  • Measures 8.5" x 11"
  • Includes complete instructions and recording sheet
  • Uses 10% calibrated Contrast Sensitivity level with Acuity
  • A new contrast sensitivity test comparable to the small letter contrast test
  • Detects subtle effects of defocus, low luminance and glare
  • 20/50 letter size at 4 meters (13 ft.)
  • Log CS increases 0.25 steps per row (0.05 log CS/ letter)
  • Includes soft-tipped pointer, recording forms and test instructions
Inquire
  • For testing at 2 meters (6.5 ft.)
  • Each page it's own contrast level at 100%, 2.5% and 1.25%
  • Acuity range 20M to 1.6M
  • Includes test instructions, recording forms (Cat. No. 2514) and soft-tipped pointer
  • Measures 13.5 X 14 in.
Product NumberPelli-Robson40702120Inquire2380
Get quoteInquireInquireInquireInquireInquire