Optical Pachymetry / Optical Pachycam

Optical pachymetry is the process in which an eye doctor measures the thickness of a patient's cornea. A device called a pachymeter is used to get the measurements needed, which can be used prior to certain eye surgeries — such as refractive surgery — or also to look for signs of glaucoma. Pachymeters are non-invasive and many of today's devices use the latest technologies to ensure very accurate measurements.
Showing 5 of 5 products
  • <<
  • >>
Get quotes for all products
Select up to 5 products from below to compare or request more information.
Compare or Get quote for selected.
TONOPACHY™ NT-530P Non Contact Tonometer / Pachymeter
  • Features:
    • Enhanced combination unit of non contact tonometer and pachymeter
    • Automatic calculation of compensated IOP
    • Advanced APC (Auto Puff Control) and noise reduction for comfortable tonometry measurement
    • Tiltable 5.7-inch color LCD for user-friendly operability
    • 3-D auto tracking, auto shot, and auto complete
    • The ACA mode allows the operator to capture an image of the anterior chamber angle with the Scheimpflug image.
  • Weight (lbs): Inquire
  • Interface: Inquire
  • Fixation: Inquire
  • Display: Inquire
  • Measurement Range: Inquire
  • Working Distance: Inquire
  • Light Source: Inquire
  • Optical Pachymetry: Inquire
  • Measuring Time: Inquire
  • Power Requirements: Inquire
  • Dimensions (W × H × D): Inquire
  • Measurement Range Setting: Inquire
Read More
Compare or Get quote for selected.
TONOREF™ III Auto Ref / Kerato / Tono / Pachymeter
  • Features: -Combination of auto refaractometer, auto keratometer, non contact tonometer and non contact pachymeter

    -High measurement accuracy
    • Large pupil zone imaging method
    • Double mire ring method
    • Automated calculation of corrected IOP
    • Patient-friendly air puff
      • Automatic Puff Control (APC)
      • Softer and quieter air puff -Gentle nozzle design
    -Clinically important functions - accommodation measurement and opacity assessment

    -User-friendly design

    -Space saving design that is a comfortable and efficient upgrade to your practice
  • Weight (lbs): Inquire
  • Interface: Inquire
  • Fixation: Inquire
  • Display: Inquire
  • Measurement Range: Inquire
  • Working Distance: Inquire
  • Light Source: Inquire
  • Optical Pachymetry: Inquire
  • Measuring Time: Inquire
  • Power Requirements: Inquire
  • Dimensions (W × H × D): Inquire
  • Measurement Range Setting: Inquire
Read More
Compare or Get quote for selected.
OCULUS PARK 1®

OCULUS PARK 1®

OCULUS, Inc.

  • Features: One quick measurement delivers:
    • refraction
    • central K-readings
    • non-contact pachymetry on a 4 mm slice
    • thinnest spot
    • IOP correction
  • Weight (lbs): Inquire
  • Interface: Inquire
  • Fixation: Inquire
  • Display: Inquire
  • Measurement Range: Inquire
  • Working Distance: Inquire
  • Light Source: Inquire
  • Optical Pachymetry: The optional, non-contact pachymetry is based on Scheimpflug images and makes precise non-contact measurement of the corneal thickness possible. - Measurement of the corneal thickness in the apex and the minimum corneal thickness in the entire measuring area - Measurement of 600 absolute height values on a horizontal 4 mm cut through the apex - Presentation of the corneal thickness profile in the form of a diagram. Automatic adjustment of the scaling of the Pachymetry measurements for better presentation of the individual thicknesses - Pachymetry-based correction of the separately measured intraocular pressure
  • Measuring Time: Inquire
  • Power Requirements: Inquire
  • Dimensions (W × H × D): Inquire
  • Measurement Range Setting: Inquire
Read More
Compare or Get quote for selected.
OCULUS Pentacam® HR

OCULUS Pentacam® HR

OCULUS, Inc.

  • Features:
    • High resolution cross sectional images of the anterior segment
    • Axial and tangential topography maps
    • Total corneal refractive power
    • Pachymetry maps
    • Anterior and posterior corneal elevation maps
    • Zernike corneal wavefront analysis
    • Anterior chamber angle measurement
    • Anterior chamber depth and volume measurements
    • 3D Lens Densitometry and Pentacam Nucleus Staging (automatic classification of lens opacity)
    • Corneal Optical Densitometry for assessing and quantifying corneal opacification
    • Fast Screening Report to quickly identifying abnormalities found in common pathologies
    • Cataract Pre-op Display for premium IOLs
    • Holladay Report with equivilent K readings
    • Keratoconus detection and staging
    • Belin/Ambrosio Enhanced Ectasia
    • Contact Lens Fitting with simulated fluorescein image
    • Various comparison displays including Compare 2 Scheimpflug
    • Network ready - Up to 50 workstations included
      Optional Features:
    • PIOL Fitting Software
    • DICOM Interface
  • Weight (lbs): Inquire
  • Interface: USB, DICOM compatible
  • Fixation: Inquire
  • Display: The Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities. Standard Software: Belin/Ambrosio Enhanced Ecstasia, Holladay Report, Contact Lens Fitting, Cataract package and Refractive Package.
  • Measurement Range: Inquire
  • Working Distance: Inquire
  • Light Source: Inquire
  • Measuring Time: Inquire
  • Power Requirements: Inquire
  • Dimensions (W × H × D): Inquire
  • Measurement Range Setting: Inquire
Read More
Compare or Get quote for selected.
iPac® Pachymeter

iPac® Pachymeter

Reichert Technologies

  • Features:
    • Bluetooth® connectivity -- send measurement data directly to your EMR system or optional wireless printer
    • One-button control
    • Rotating color LCD
    • Rechargeable Lithium-ion battery
    • Charge using provided USB cable or optional charging cradle
    • Ergonomic design
    • ADA tax benefit eligibility
    • Three year warranty
  • Weight (lbs): Inquire
  • Interface: Inquire
  • Fixation: Inquire
  • Display: Inquire
  • Working Distance: Inquire
  • Light Source: Inquire
  • Optical Pachymetry: Inquire
  • Measuring Time: Inquire
  • Power Requirements: Inquire
  • Dimensions (W × H × D): Inquire
  • Measurement Range Setting: Inquire
Read More
Select up to 5 products from above to compare or request more information.