YAG Laser and SLT (Selective Laser Trabeculoplasty)

Both Selective Laser Trabeculoplasty (SLT) and YAG laser treatment are used to treat medication conditions within the anterior segment of the eye. SLT is a type of laser surgery used to help lower intraocular pressure (IOP) in glaucoma patients, while YAG lasers can be used in both glaucoma and cataract surgeries. Some of the devices below offer ophthalmologists both SLT and YAG photodisruption capabilities in one unit, helping to cut down on the space required for multiple devices.
Showing 6 of 6 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.

Featured products

Compare for selected.
Tango Reflex™ SLT/YAG Multi-Modality Laser
  • Features:
    • Premium capsulotomy, iridotomy and Selective Laser Trabeculoplasty
    • Dual-mode laser cavity: 532nm and 1064nm
    • Optimized optical system, which includes True Coaxial Illumination - TCI - ensuring superior visualization in both the anterior and posterior segments
    • Posterior membranectomy
  • Weight (lbs): 68 lbs (31 kg) (laser only)
  • Energy: SLT mode: 0.3 to 2.6 mJ per pulse, continuously variable
    YAG mode: 0.3 to 10 mJ per pulse, continuously variable
  • Wavelength:
    • SLT mode: green 532 nm

    • YAG mode: infrared 1064 nm
  • Pulse Duration: Inquire
  • Repetition Rate: up to 4 Hertz
  • Power Requirements: 100–240 VAC, 50/60 Hz, 800 VA
  • Cooling: Air cooled
  • Laser Source: SLT mode: Q-switched, frequency doubled Nd:YAG
    YAG mode: Q-switched Nd:YAG
  • Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
  • Aiming Beam: SLT mode: red 635 nm, adjustable intensity
    YAG mode: green 515 nm, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Tango: SLT/YAG Combination Laser System
  • Features:
    • Selective Laser Trabeculoplasty, capsulotomy and iridotomy
    • Dual-mode laser cavity: 532nm and 1064nm
    • Custom-designed optics optimized for enhanced anterior segment visualization
  • Weight (lbs): 68 lbs (31 kg) (laser only)
  • Energy: SLT Mode: 0.3 to 2.6 mJ, per pulse, continuously variable
    YAG Mode: 0.3 to 10 mJ, per pulse, continuously variable
  • Wavelength: SLT Mode: green: 532 nm
    YAG Mode: 1064 nm
  • Pulse Duration: SLT Mode: 3 ns
    YAG Mode: 4 ns
  • Repetition Rate: up to 3 hertz
  • Power Requirements: 100-240 VAC, 50/60 Hz, 800 VA
  • Cooling: air cooled
  • Laser Source: Inquire
  • Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
  • Aiming Beam: red 635 nm, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Selecta Duet™ SLT and YAG Photodisruptor
  • Features:
    • Proprietary advanced laser design, with automatic internal tests to ensure power requirements and a secondary control unit to guarantee power accuracy.
    • Highly-accurate Super Gaussian beam profile in YAG mode
    • Table is equipped with built-in compact storage space for lenses or other accessories
    • Ergonomically designed joystick includes a convenient integrated laser fire-switch.
    • Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
    • Slit lamp function includes a 6-step magnification changer.
    • Table height can be easily adjusted using its electronic up/down switch
  • Weight (lbs): <60 kg>
  • Energy: YAG: 0.3mJ - 10mJ per pulse
    SLT: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 increments
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
  • Pulse Duration: 3ns (nanoseconds)
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Pulse Mode: YAG: 1, 2 or 3 pulses per burst (selectable)
    SLT: Single pulse
Read More
Inquire
Compare for selected.
Selecta Trio™ YAG Laser, SLT and Photocoagulation
  • Features:
    • Homogeneous Laser Beam in Photo-Coagulator mode
    • Dual Fiber Port -- Instantly switch between delivery devices
    • ClearView™ Filters -- Optimized view of treatment site
    • AcuGuide™ Micromanipulator for accurate and safe laser beam guidance for fine-tuned laser application on target tissue.
    • Integrated LaserLink Cradle safely and conveniently stow
    • Table is equipped with built-in compact storage space for lenses or other accessories
    • The ergonomically designed joystick includes a convenient integrated laser fire-switch.
    • Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
    • Slit lamp function includes a 6-step magnification changer.
    • Table height can be easily adjusted using its electronic up/down switch.
  • Weight (lbs): Inquire
  • Energy: YAG: 0.3ml - 10ml per pulse
    SLT: 0.3 - 2ml per pulse, continously variable in 0.1 increments
    PC: 50 - 2500mW
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
    PC: 532 nm
  • Pulse Duration: YAG: 3 ns
    SLT: 3 ns
    PC: 0.01-3 seconds
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
    PC: N/A
  • Power Requirements: Inquire
  • Cooling: YAG & SLT: Air cooled
    PC: Air cooled, enhanced with TEC
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags