Tango Reflex™ SLT/YAG Multi-Modality Laser
Ellex
Weight (lbs):
68 lbs (31 kg) (laser only)
Spot Size:
SLT mode: 400 µm
YAG mode: 8 µm
Pulse Duration:
Inquire
Repetition Rate:
up to 4 Hertz
Power Requirements:
100–240 VAC, 50/60 Hz, 800 VA
Laser Source:
SLT mode: Q-switched, frequency doubled Nd:YAG
YAG mode: Q-switched Nd:YAG
Dimensions (W × H × D):
75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
Aim Beam:
SLT mode: red 635 nm, adjustable intensity
YAG mode: green 515 nm, adjustable intensity
Laser Wavelength:
Inquire
Energy Levels:
Inquire
Pulse Mode:
Inquire
Offset:
SLT mode: not applicable
YAG mode: 0 to ± 500 µm, continuously variable
Description:
Tango Reflex™ from Ellex combines multiple treatment platforms — SLT for glaucoma, premium capsulotomy and posterior membranectomy – in a single laser system. Featuring an intuitive tablet user interface, the multi-modality Tango Reflex™ allows you to perform the full range of anterior and posterior YAG laser procedures, as well as SLT, with greater precision and clinical efficacy.
Read More
Inquire
Compare
for selected.
Tango: SLT/YAG Combination Laser System
Ellex
Weight (lbs):
68 lbs (31 kg) (laser only)
Magnification:
optimized for enhanced anterior segment visualization
Spot Size:
SLT Mode: 400 µm
YAG Mode: 8 µm
Pulse Duration:
SLT Mode: 3 ns
YAG Mode: 4 ns
Repetition Rate:
up to 3 hertz
Power Requirements:
100-240 VAC, 50/60 Hz, 800 VA
Laser Source:
Inquire
Dimensions (W × H × D):
75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
Aim Beam:
red 635 nm, adjustable intensity
Laser Wavelength:
Inquire
Energy Levels:
Inquire
Pulse Mode:
Inquire
Offset:
Inquire
Description:
Whether you’re seeking to treat glaucoma, or you’re performing capsulotomy or iridotomy procedures, Tango™, with its fully featured SLT laser and its powerful, precise YAG laser, will enable you to secure the results you and your patients are looking for — consistently and to the highest standard. Choose Tango™ from Ellex, and you’ll be able to move effortlessly between SLT and YAG modes, which means you can treat patients with glaucoma and secondary cataract with maximum accuracy and optimal efficacy.
Read More
Inquire
Compare
for selected.
Ultra Q Reflex™
Ellex
Weight (lbs):
31kg, 68 lbs (laser only)
Magnification:
optimized for enhanced anterior segment visualization
Spot Size:
8 µm
Pulse Duration:
4 ns
Repetition Rate:
up to 4 hertz
Power Requirements:
100-240 VAC, 50/60 Hz, 800 VA
Laser Source:
Q-switched Nd: YAG
Dimensions (W × H × D):
75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
Aim Beam:
green 515 nm, adjustable intensity
Laser Wavelength:
1064 nm
Energy Levels:
0.3 to 10 mJ, single pulse, continuously variable
Pulse Mode:
Inquire
Description:
Ultra Q Reflex™ is the platform that enables you to perform the full range of anterior and posterior YAG laser procedures, including posterior membranectomy, premium capsulotomy and iridotomy procedures to the highest standards of safety, accuracy, and efficacy.
Read More
Inquire
Compare
for selected.
Ultra Q™: Premier YAG Laser Photodisruptor
Ellex
Weight (lbs):
66 lbs (30 kg) (laser only)
Magnification:
optimized for enhanced anterior segment visualization
Spot Size:
8 µm
Pulse Duration:
4 ns
Repetition Rate:
up to 3 hertz
Power Requirements:
100-240 VAC, 50/60 Hz, 500 VA
Laser Source:
Q-switched Nd: YAG
Dimensions (W × H × D):
75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in)
Laser Wavelength:
1064 nm
Energy Levels:
0.3 to 10 mJ, single pulse, continuously variable
Pulse Mode:
Inquire
Offset:
100 to 350 µm, continuously variable
Description:
Whether you’re seeking to perform capsulotomies for Presbyopic IOLs or peripheral iridotomies prior to the insertion of Phakic IOLs, it’s imperative that your treatment equipment delivers excellent results every day. Ultra Q™ has been created by Ellex to ensure you achieve your goals — delivering precision, perfectly and consistently, maximizing patient satisfaction.
Read More
Inquire
Select All
Select up to 5 products from above to compare or request more information.
Compare
Tags:
Please Login or Register to Create Tags
Feedback
Articles
YAG Laser Cataract Surgery
Selective Laser Trabeculoplasty (SLT): Maximizing Success, The Next Refractive Surgeon’s Laser
Nd:YAG Lasers in Ophthalmology
Ultra Q: Premier YAG Laser Photodisruptor
Optimis Fusion SLT/YAG Laser
What to do in Boston During the ASCRS 2014
Webinar: YAG Laser Vitreolysis: A Safe and Effective Alternative For Vitrectomy EURETINA/ESCRS 2014 WEBINAR
Visionary Venture Fund to Invest $30M in Promising Ophthalmology Companies
Mynosys Receives FDA Clearance for Zepto Capsulotomy System
Technique Tips for Treating Posterior Polar Cataracts
Case Report: The Disappearing Capsulotomy
Case Report: Refractive Surprise after Cataract Surgery
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
advertisement
Related Articles
Charting a Positive Financial Course for ...
Friday, July 07, 2023
Global Survey Reveals Misconceptions around ...
Thursday, June 22, 2023
The Effectiveness of Cryopreserved Amniotic ...
Wednesday, May 10, 2023
FDA Approves the CT LUCIA 621P Monofocal IOL
Wednesday, April 26, 2023
Fully Assisted Refraction System for TS-610 Aims ...
Wednesday, December 14, 2022
AdGlare RMR2