Holladay Automated Contrast Sensitivity System&trade; (HACSS)
  • Features:
    • Testing for CSF Under Glare Conditions at low, medium or high luminance levels. Can be performed at either mesopic or photopic luminance levels
    • Preferred Optotypes; Rotationally symmetric targets and randomly presented optotypes. Eliminates biases from the patient with non-rotational symmetric optical aberrations such as residual astigmatism, trefoil, coma, etc.
    • ANSI & ISO Guideline Conformance; Conducts contrast sensitivity testing at (1.5, 3, 6, 12 and 18) cycles per degree and at light levels of 85 cd/m2 (photopic) and 3 cd/m2 (mesopic). Plus, includes all of the options and parameters the agencies require for contrast testing
    • Conduct Standard Vision Testing; Integrate with the M&S Smart System comprehensive visual acuity, contrast sensitivity, fixation and video display systems. Approved for clinical trials using the eETDRS and ATS protocols for visual acuity
    • Quick Test Feature that reduces test time on patient return visits by starting at 0.3 log units above previous threshold, minimizing test time to less than 3 minutes per eye
    • Automated-user interactive testing eliminates technician bias or erroneous data
    • Store multiple test results by patient to track changes in CSF function over time; results can be stored locally or transferred to any media storage device
    • Graph, compare and print patent results against normative data
    • Utilizes Smart System integrated database to store and transmit test results within minutes of test completion via internet connections
Read More
Inquire
Compare for selected.
Linear Sine Wave Grating with Normative Data
  • Features:
    • Utilize automated protocol that provides results with normative data or manually test patients using the M&S Remote Control or Keypad
    • Measure contrast at ANSI Standard 18, 12, 6, 3 and 1.5 Cycles/Degree from 100% to 0.8% contrast
    • Normative data study conducted in 2010 by Illinois College of Optometry
    • All targets are precisely sized according to the testing distance for maximum accuracy
    • Test in under 5 min
    • Perfect for monitoring progression of cataracts and assessing quality of vision
    • Display a graph comparing your patient’s results to normative data at the end of the testing algorithm