Both Selective Laser Trabeculoplasty (SLT) and YAG laser treatment are used to treat medication conditions within the anterior segment of the eye. SLT is a type of laser surgery used to help lower intraocular pressure (IOP) in glaucoma patients, while YAG lasers can be used in both glaucoma and cataract surgeries. Some of the devices below offer ophthalmologists both SLT and YAG photodisruption capabilities in one unit, helping to cut down on the space required for multiple devices.
Select up to 5 products from below to compare or request more information.
Featured products
- Features: A suite of technologies has been incorporated in these lasers to achieve seamless function and greater precision. Features for targeting pathology, accurate energy delivery, and operative assist functions allow the surgeon to deliver treatments “Right on the Mark”.
- Refined Laser Delivery with Lower Energy
The YC-200 S plus / YC-200 achieves 1.6 mJ plasma threshold in air*, delivering accurate and robust treatments with lower energy.
*A plasma threshold of 1.6 mJ is achieved in ordinary room conditions (in-house data).
- SLT-NAVI*
The SLT-NAVI feature presents an intuitive display on the progress of laser treatment, providing the surgeon with important feedback.
*Available for the YC-200 S plus
- Clear and Sharp Field of View
An improved optical design that optimizes resolution and contrast, and an expanded focal depth provide a clear view of pathology and treatment.
- Precise Aiming Beam
Motorized Rotatable Aiming Beam (YAG Mode)
The dual aiming beam offers superior targeting with a 360° rotating aiming beam that can avoid corneal opacities and achieve more accurate focusing.
Precise Edge Aiming Beam (SLT Mode*)
Parfocality delivers a clear view for easier focusing of the aiming beam through the contact lens.
*Available for the YC-200 S plus
- Optimized Operating Distance*
Maximized working distance allows easier manipulation of the contact lens, and the short operating distance decreases surgeon fatigue during treatment.
*Operating distance denotes the distance from the microscope eyepiece to the patient’s eye.
- Unique Joystick
Utility S-switch
The S-switch on the joystick changes treatment settings without shifting gaze from the oculars. The ease of use allows surgeons an increased level of comfort during treatment.
- Weight (lbs): Inquire
- Energy: Inquire
- Wavelength: Inquire
- Pulse Duration: Inquire
- Repetition Rate: Inquire
- Power Requirements: Inquire
- Cooling: Inquire
- Laser Source: Inquire
- Dimensions (W × H × D): Inquire
- Aiming Beam: Inquire
- Pulse Mode: Inquire
Read More
- Features: Quantel Medical’s proprietary technology is based on an engineering breakthrough, which enables infrared and visible green nanosecond pulses to be produced by single dual-mode cavity: 532nm and 1064nm.
This last technology reduces complexity and results in a more elegant, advanced combination laser platform.
Optimis Fusion includes convergent optical path allowing an optimized visualization of both anterior and posterior segment, a better visual comfort, combined with a blue-free LED illumination.
A Glaucoma, Cataract and Retina Laser in One :
Optimis Fusion easily combines with Quantel Medical Vitra or Vitra Multispotgreen photocoagulators.
Main characteristics:
- Advanced technology: dual-mode laser cavity, 532nm and 1064nm
- Premium Optics
- Integrated platform with a compact footprint
- A Glaucoma, Cataract and Retina Laser platform combined with Vitra or Vitra Multispot
- Weight (lbs): 24.15 kg (53.1 lbs)
- Energy:
- SLT: 0.3 to 2 mJ
- YAG:0,3 ta 10 mJ (1 pulse)
- Wavelength:
- Pulse Duration: 4 ns
- Repetition Rate:
- SLT: Up to 2.5 Hz
- YAG: Up to 2 Hz
- Power Requirements: 100-240 VAC, 50/60 Hz
- Cooling: Air cooled
- Laser Source:
- SLT: Q-switched, frequency doubled Nd:YAG
- YAG: Q-switched Nd:YAG
- Dimensions (W × H × D):
- 54 cm x 64.7 cm x 48.5 cm
- 21.3" x 25,5" x 48.5"
- Aiming Beam: Red 635 nm, adjustable intensity
- Pulse Mode:
- SLT: Single pulse
- YAG: 1, 2 and 3 pulses per shot
Read More
Inquire
- Features:
- Premium capsulotomy, iridotomy and Selective Laser Trabeculoplasty
- Dual-mode laser cavity: 532nm and 1064nm
- Optimized optical system, which includes True Coaxial Illumination - TCI - ensuring superior visualization in both the anterior and posterior segments
- Posterior membranectomy
- Weight (lbs): 68 lbs (31 kg) (laser only)
- Energy: SLT mode: 0.3 to 2.6 mJ per pulse, continuously variable
YAG mode: 0.3 to 10 mJ per pulse, continuously variable - Wavelength:
- SLT mode: green 532 nm
- YAG mode: infrared 1064 nm
- Pulse Duration: Inquire
- Repetition Rate: up to 4 Hertz
- Power Requirements: 100–240 VAC, 50/60 Hz, 800 VA
- Cooling: Air cooled
- Laser Source: SLT mode: Q-switched, frequency doubled Nd:YAG
YAG mode: Q-switched Nd:YAG - Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
- Aiming Beam: SLT mode: red 635 nm, adjustable intensity
YAG mode: green 515 nm, adjustable intensity - Pulse Mode: Inquire
Read More
Inquire
- Features:
- Selective Laser Trabeculoplasty, capsulotomy and iridotomy
- Dual-mode laser cavity: 532nm and 1064nm
- Custom-designed optics optimized for enhanced anterior segment visualization
- Weight (lbs): 68 lbs (31 kg) (laser only)
- Energy: SLT Mode: 0.3 to 2.6 mJ, per pulse, continuously variable
YAG Mode: 0.3 to 10 mJ, per pulse, continuously variable - Wavelength: SLT Mode: green: 532 nm
YAG Mode: 1064 nm - Pulse Duration: SLT Mode: 3 ns
YAG Mode: 4 ns - Repetition Rate: up to 3 hertz
- Power Requirements: 100-240 VAC, 50/60 Hz, 800 VA
- Cooling: air cooled
- Laser Source: Inquire
- Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
- Aiming Beam: red 635 nm, adjustable intensity
- Pulse Mode: Inquire
Read More
Inquire
- Features:
- Proprietary advanced laser design, with automatic internal tests to ensure power requirements and a secondary control unit to guarantee power accuracy.
- Highly-accurate Super Gaussian beam profile in YAG mode
- Table is equipped with built-in compact storage space for lenses or other accessories
- Ergonomically designed joystick includes a convenient integrated laser fire-switch.
- Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
- Slit lamp function includes a 6-step magnification changer.
- Table height can be easily adjusted using its electronic up/down switch
Weight (lbs): <60 kg>60 kg>Energy: YAG: 0.3mJ - 10mJ per pulse
SLT: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 incrementsWavelength: YAG: 1064 nm
SLT: 532 nmPulse Duration: 3ns (nanoseconds)Repetition Rate: YAG: 3Hz (in single burst)
SLT: 3HzPower Requirements: InquireCooling: InquireLaser Source: InquireDimensions (W × H × D): InquireAiming Beam: Red Diode, continuously variable adjustable intensityPulse Mode: YAG: 1, 2 or 3 pulses per burst (selectable)
SLT: Single pulse
Read More
Inquire
- Features:
- Homogeneous Laser Beam in Photo-Coagulator mode
- Dual Fiber Port -- Instantly switch between delivery devices
- ClearView™ Filters -- Optimized view of treatment site
- AcuGuide™ Micromanipulator for accurate and safe laser beam guidance for fine-tuned laser application on target tissue.
- Integrated LaserLink Cradle safely and conveniently stow
- Table is equipped with built-in compact storage space for lenses or other accessories
- The ergonomically designed joystick includes a convenient integrated laser fire-switch.
- Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
- Slit lamp function includes a 6-step magnification changer.
- Table height can be easily adjusted using its electronic up/down switch.
- Weight (lbs): Inquire
- Energy: YAG: 0.3ml - 10ml per pulse
SLT: 0.3 - 2ml per pulse, continously variable in 0.1 increments
PC: 50 - 2500mW - Wavelength: YAG: 1064 nm
SLT: 532 nm
PC: 532 nm - Pulse Duration: YAG: 3 ns
SLT: 3 ns
PC: 0.01-3 seconds - Repetition Rate: YAG: 3Hz (in single burst)
SLT: 3Hz
PC: N/A - Power Requirements: Inquire
- Cooling: YAG & SLT: Air cooled
PC: Air cooled, enhanced with TEC - Laser Source: Inquire
- Dimensions (W × H × D): Inquire
- Aiming Beam: Red Diode, continuously variable, adjustable intensity
- Pulse Mode: Inquire
Read More