Fluorescein Angiogram / Fundus Fluorescein Angiography

Not all eye tests can be accomplished by optics alone; some, such as retinal circulation examinations, require the use of fluorescein dyes to track the movement of fluids. Fluorescein angiography refers to the injection of dyes into the retina that fluoresce when illuminated by an optical instrument. The following angiography systems are optimized for fluorescein use; however, some can perform indocyanine-green aniography as well as fundus-autofluorescence. Five megapixel-and-above CCDs provide high-resolution and 3D images of all layers of the eye. The customer should seek a system with innovations such as cloud-based data storage, permitting analysis on a smart-phone. With the increasing desire for all-in-one technology in mind, many of these systems integrate and interface with other eye examination equipment; therefore, the customer should consider systems they already have but could benefit from expansion.
Showing 8 of 8 products
  • <<
  • >>
Get quotes for all products
Select up to 5 products from below to compare or request more information.

Featured products

Compare for selected.
SPECTRALIS Diagnostic Imaging Platform

SPECTRALIS Diagnostic Imaging Platform

Heidelberg Engineering, Inc.

  • Weight (lbs): Inquire
  • Working Distance: Inquire
  • Photographic Angles: 30° x 30°; optional 55° lens
  • Film: Inquire
  • Image Magnification/Resolution: 10 µm/pixel
  • Digital Imaging (Y/N): Yes
  • Light Source: 820 nm laser; 870 nm SLD
  • Connectivity: Yes
  • Power Consumption: Inquire
  • Fixation Targets: Inquire
  • Scan Depth: 1.9 mm
  • Refractive Error Compensation: Inquire
  • A-Scan Speed: Inquire
  • Axial Resolution: 3.9 µm (digital)
  • Transverse Resolution: 14 µm
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Inquire
Compare or Get quote for selected.
CX-1 Hybrid Digital Mydriatic/Non-Mydriatic Retinal Camera
  • Weight (lbs): 57 pounds (26 kg)
  • Working Distance: 35 mm from the front of objective lens
  • Photographic Angles: Inquire
  • Film: Inquire
  • Image Magnification/Resolution: Inquire
  • Digital Imaging (Y/N): Inquire
  • Light Source: Mydriatic: halogen lamp for observation, xenon tube for photography
    Non-Mydriatic: IRED for observation, xenon tube for photography
  • Connectivity: Inquire
  • Fixation Targets: Mydriatic: external type (Standard), internal type (Optional)
    Non-Mydriatic: internal fixation target (LED dot matrix, green)
  • Dimensions (W × H × D): 320 mm (12.6 in) x 577 mm (22.3 in) x 531 mm (20.9 in)
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: Color, FA, Red Free, Cobalt, FAF
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Compare or Get quote for selected.
Retina Scan Duo™2 OCT / Fundus Camera
  • Weight (lbs): Inquire
  • Working Distance: Inquire
  • Photographic Angles: Inquire
  • Film: Inquire
  • Image Magnification/Resolution: Inquire
  • Digital Imaging (Y/N): Inquire
  • Light Source: Inquire
  • Connectivity: Inquire
  • Power Consumption: Inquire
  • Fixation Targets: Inquire
  • Dimensions (W × H × D): Inquire
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: Inquire
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Compare or Get quote for selected.
California Ultra-widefield Retinal Imaging System
  • Weight (lbs): 34 kg / 75 lbs
  • Working Distance: Inquire
  • Photographic Angles: Inquire
  • Film: Inquire
  • Image Magnification/Resolution: optomap: 20 µm
    optomap plus, af, fa, icg: 14 µm
  • Digital Imaging (Y/N): Inquire
  • Light Source: Inquire
  • Connectivity: Inquire
  • Power Consumption: Max. 300 VA
  • Fixation Targets: Inquire
  • Dimensions (W × H × D): 550 x 608 to 632 x 550 mm
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: optomap and optomap plus (red and green laser):
    • Color composite
    • green laser View
    • red laser View
    optomap af (green laser): autofluorescence
    optomap fa (blue laser): fluorescein angiography
    optomap icg (infra-red): indocyanine green angiography
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Compare or Get quote for selected.
TRC-50DX Mydriatic Retinal Camera
  • Weight (lbs): Inquire
  • Working Distance: 39mm [1.5 in.]
  • Photographic Angles: 50°,35°, and 20° angles of coverage
  • Film: 35mm
  • Image Magnification/Resolution: Photographic magnification: With 35 mm camera at zero diopter: 1.84X at 50°, 2.45X at 35° and 4.28X at 20°
    Total observation magnification (at zero diopter): 10X at 50°, 13.3X at 35° and 23.3X at 20°
  • Digital Imaging (Y/N): Yes
  • Light Source: Inquire
  • Connectivity: Inquire
  • Power Consumption: Inquire
  • Fixation Targets: Inquire
  • Dimensions (W × H × D): Inquire
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: Inquire
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Compare or Get quote for selected.
TRC-NW8F Myd/Non-Myd Retinal Camera
  • Weight (lbs): Inquire
  • Working Distance: 40.7 mm
  • Photographic Angles: 45°
  • Film: Inquire
  • Image Magnification/Resolution: 12.3MP resolution
  • Digital Imaging (Y/N): Yes
  • Light Source: Inquire
  • Connectivity: Inquire
  • Power Consumption: Inquire
  • Fixation Targets: Inquire
  • Dimensions (W × H × D): Inquire
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: Inquire
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Compare for selected.
FF 450<sup><i>plus</i></sup> Fundus Camera with VISUPAC™ Digital Imaging System
  • Weight (lbs): Inquire
  • Working Distance: 42mm
  • Photographic Angles: Inquire
  • Film: Optional
  • Image Magnification/Resolution: Dependent on sensor configuration
  • Digital Imaging (Y/N): Yes - VISUPAC Digital Imaging and Archive Management
  • Light Source: Inquire
  • Connectivity: Inquire
  • Power Consumption: Inquire
  • Fixation Targets: Internal / External
  • Dimensions (W × H × D): Inquire
  • Scan Depth: Inquire
  • Refractive Error Compensation: Inquire
  • Image Type: Inquire
  • A-Scan Speed: Inquire
  • Axial Resolution: Inquire
  • Transverse Resolution: Inquire
  • Field Angle/Angle of View: Inquire
  • Viewing Magnification: Inquire
Read More
Inquire