Corneal Topography also referred to as Photokeratoscopy and Videokeratoscopy, is a technique that is used to map the curved surface of the Cornea. This can help measure the quality of vision as well as assist in LASIK surgery and the fitting of contact lenses. This procedure is non-invasive and painless to the patient. These procedures are the most common among Ophthalmology and Optometry practices and ample consideration for Corneal Topography is important.
Some vendors offer Corneal Topographers that also include other applications; such as Pupillometers and Tear film analyzers. When purchasing a Corneal Topographer, decide on which applications are necessary and consider future growth of a practice. A product that encompasses multiple applications may fit best.
|  |  |  |
| Company | OCULUS, Inc. | OCULUS, Inc. | OCULUS, Inc. |
| Item | OCULUS Pentacam® AXL Wave | OCULUS Pentacam® AXL | OCULUS Pentacam® HR |
| Price | | | |
| Vendor Product Page | | Company Product Page | Company Product Page |
| Description | The Pentacam® AXL Wave is the best and most time-saving solution available, providing new perspectives you’ve never seen before!
- Wavefront Aberrometry of the Entire Eye - Low and high order aberrations of the whole eye are measured using
| The Pentacam® AXL is a systematic enhancement of the time-tested Pentacam® HR technology. In addition to anterior segment tomography, the original function of its predecessor, the Pentacam® AXL has integrated axial length measurement, a | The Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total |
| Features | - Scheimpflug based Tomography
- Optical Biometry
- Wavefront Aberrometry of the entire eye
- Objective Refraction
- Retroillumination
| - High resolution cross sectional images of the anterior segment
- Optical Biometry Axial Length measurement
- IOL Calculation Display with Standard, Post Refractive, and Toric Formulas
- Axial and tangential topography maps
- Total corneal refractive power
- Pachymetry maps
- Anterior and posterior corneal elevation maps
- Zernike corneal wavefront analysis
- Anterior chamber angle measurement
- Anterior chamber depth and volume measurements
- 3D Lens Densitometry and Pentacam Nucleus Staging (automatic classification of lens opacity)
- Corneal Optical Densitometry for assessing and quantifying corneal opacification
- Fast Screening Report to quickly identifying abnormalities found in common pathologies
- Cataract Pre-op Display for premium IOLs
- Holladay Report with equivilent K readings
- Keratoconus detection and staging
- Belin/Ambrosio Enhanced Ectasia
- Contact Lens Fitting with simulated fluorescein image
- Various comparison displays including Compare 2 Scheimpflug
- Network ready - Up to 50 workstations included
Optional Features: - PIOL Fitting Software
- DICOM Interface
| - High resolution cross sectional images of the anterior segment
- Axial and tangential topography maps
- Total corneal refractive power
- Pachymetry maps
- Anterior and posterior corneal elevation maps
- Zernike corneal wavefront analysis
- Anterior chamber angle measurement
- Anterior chamber depth and volume measurements
- 3D Lens Densitometry and Pentacam Nucleus Staging (automatic classification of lens opacity)
- Corneal Optical Densitometry for assessing and quantifying corneal opacification
- Fast Screening Report to quickly identifying abnormalities found in common pathologies
- Cataract Pre-op Display for premium IOLs
- Holladay Report with equivilent K readings
- Keratoconus detection and staging
- Belin/Ambrosio Enhanced Ectasia
- Contact Lens Fitting with simulated fluorescein image
- Various comparison displays including Compare 2 Scheimpflug
- Network ready - Up to 50 workstations included
Optional Features: - PIOL Fitting Software
- DICOM Interface
|
| Approval | Inquire | US FDA | US FDA |
| Interface | Inquire | USB, DICOM compatible | USB, DICOM compatible |
| Display | Inquire | The Pentacam® AXL offers various displays such as: Axial Length, IOL Calculation, Cataract Pre-Op, Topography maps of the anterior and posterior corneal surface, Belin/Ambrosio Enhanced Ectasia, Corneal Densitometry, Fast Screening Report, Overview of all captured Scheimpflug images, Pachymetry maps, absolute and relative, Elevation maps of the anterior and posterior corneal surface, 3D Anterior chamber analysis, Anterior segment tomography, General overview display, Keratoconus detection and classification, topometrically, Four maps, refractive, Comparative and differential analysis of two examinations, Comparison and super imposition of Scheimpflug images | The Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities. Standard Software: Belin/Ambrosio Enhanced Ecstasia, Holladay Report, Contact Lens Fitting, Cataract package and Refractive Package. |
| Get quote | | | |