Retinal Photocoagulation Laser

Retinal Photocoagulation Lasers are used to treat a variety of eye diseases including the two leading causes of blindness in the United States: Diabetic Retinopathy and Age-related Macular Degeneration. This precision laser can lower the risk of vision loss by cauterizing ocular blood vessels. Two types of Photocoagulation Lasers are used for conditions like Diabetic Retinopathy. The first is Focal Photocoagulation, which treats specific leaking blood vessels in the retina. The second is Scatter or Pan-retinal Photocoagulation; this type is used for more widespread damage over the retina. The risk of using a Retinal Photocoagulation Laser are low and side affects are rarely severe. Retinal Photocoagulation Lasers are often combined with other lasers to encompass a multitude of Ophthalmological surgical procedures. Deciding on which Retinal Photocoagulation Laser or combination laser for your practice depends on practice size, common procedures, patient dynamics as well as monetary investment.
Showing 15 of 23 products
Get quotes for all products
Select up to 5 products from below to compare or request more information.
Compare for selected.
Integre Pro Scan™ Multi-Color Pattern Scanning Photocoagulator
  • Weight (lbs): 35kg, 77 lbs. (laser only)
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Laser Compatibility: Inquire
  • Patterns:
    • Linear (2 to 7 spots)
    • Rectangle (2×3, 2×4, 2×5, 2×6, 2×7)
    • Square (2×2, 3×3, 4×4, 5×5, 6×6)
    • Triangle (3, 6, 10, 15, 21 and 28 spots)
    • Circle – filled (7, 12, 19, 27 and 37 spots)
    • Circle – empty (12, 18, 24 and 30 spots)
    • Single Half Circle (4, 7 and 10 spots)
    • Double Half Circle (11, 17 and 23 spots)
    • Circle Sector 60 (3 to 7 spots)
    • Circle Sector 120 (5, 7, 9 and 11 spots)
    • Double Circle Sector 60 (5, 7, 9 and 11 spots)
    • Double Circle Sector 120 (8, 12, 16 and 20 spots)
    • Variable curve, double curve and filled sector
  • Power Input: Inquire
  • Number of Wavelengths: 1. yellow-red configuration: 561 nm and 670 nm
    2. yellow configuration: 561 nm
    3. green configuration: 532 nm
  • Treatment Pulse Durations: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare for selected.
Integre Pro™ All-In-One Laser/Slit Lamp Photocoagulator
  • Features:
    • Retinal laser photocoagulation
    • Multi-colour photocoagulation 561nm or 532nm
    • Optional 670nm Red wavelength
  • Weight (lbs): 77 lbs (35kg) (laser only)
  • Portability: Inquire
  • Power (V): 100-240 VAC, 50/60 Hz, 800 VA
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: 50 to 1000 µm, continuously variable
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): 76 cm (30 in) x 62 cm (24 in) x 47 cm (19 in)
  • Number of Wavelengths: 1. yellow-red configuration: 561 nm and 670 nm
    2. yellow configuration: 561 nm
    3. green configuration: 532 nm
  • Treatment Pulse Durations: Inquire
  • Aim Beam: red 635 nm, adjustable intensity
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare or Get quote for selected.
IRIDEX IQ 577™ Retina Laser System
  • Features:
    • True yellow, 577 nm wavelength for peak absorption in oxygenated hemoglobin
    • Patented MicroPulse technology for Fovea-friendly™ MicroPulse Laser Therapy for retinal disorders, and repeatable MicroPulse Laser Trabeculoplasty for glaucoma therapy
    • DualSense™ provides quick and simple selection of multiple delivery devices for RFID and SMA
    • Voice confirmation to aid surgical techniques
    • Intuitive graphical touch screen interface with high contrast color display
  • Weight (lbs): 19.2 lb (9.0 kg)
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: 100-240 VAC, 50/60 Hz
  • Dimensions (W × H × D): 12 in (30 cm) x 8.5 in (21 cm) x 14 in (35 cm)
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Diode laser, 635 nm nominal
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare or Get quote for selected.
IRIDEX OcuLight GL/GLx Green (532 nm) Laser Family
  • Features:
    • Includes TrueCW™ laser pulses for maximum control and precision
    • Designed for durability, with a thermal management system to increase laser conversion efficiency and reliability
    • Enhances user interface with conveniently located, easily understood controls
    • Allows easy transport between rooms and offices
  • Weight (lbs): 13.2 lbs (<6.0 kg)>
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: 100–240 VAC, 50/60 Hz
  • Dimensions (W × H × D): 12 in (30 cm) x 6 in (15 cm) x 12 in (30 cm)
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Diode laser, 635 nm nominal
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare or Get quote for selected.
OcuLight TX 532 nm Laser
  • Features:
    • Includes TrueCW™ laser pulses for maximum control and precision
    • Designed for durability, with a thermal management system to increase laser conversion efficiency and reliability
    • Enhances user interface with conveniently located, easily understood controls
    • Allows easy transport between rooms and offices
  • Weight (lbs): 13.2 lbs (<6.0 kg)>
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: 100–240 VAC, 50/60 Hz
  • Dimensions (W × H × D): 12 in (30 cm) x 6 in (15 cm) x 12 in (30 cm)
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Diode laser, 635 nm nominal
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare for selected.
Array LaserLink™ Pattern Scanning Laser Technology
  • Features:
    • Links with Lumenis lasers and attaches to most popular slit lamps
    • Features multi-wavelength technology and single spot, pulse mode and various pattern treatment options
    • Intuitive touchscreen presents logical workflow
    • Custom touchpad is easily moved for use with right or left hand and provides Eyes Forward Control
    • Heads up display seen as text on the retina, shows confirmation of important parameter changes
    • Frame mode displays a precise outline of the area in which the pattern will be administered
    • Titrate mode is used to establish appropriate pattern laser parameters with a single spot
    • Contact lens menu lists commonly used lenses for calculation of laser spot size on the retina
  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Laser Compatibility: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare for selected.
Novus Spectra Photocoagulator
  • Features:
    • Next-generation DPSS technology drives 2.5 W of power
    • Compatible with your preferred Slit Lamp
    • Compact, lightweight and space-saving *Patented SureSpot Optics
    • Designed for the busy practice with high patient throughput
  • Weight (lbs): 17.5 lbs (8 kg)
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: LaserLink Z-1000 Slit Lamp Adaptor (for Zeiss ® SL 130, 30SL, 20SL and 125SL); Converging Optics Laser Link, Keeler ® & Heine® LIO
    Comprehensive selection of standard, straight, curved, aspirating, illuminating, stepped and directional endophotocoagulation probes in 20, 23 and 25 gauge sizes, among others
  • Slit Lamp: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Contrasting color, adjustable intensity 635 nm nominal, <1.0 mw>
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare for selected.
Vision One Photocoagulation Laser
  • Features:
    • Modular and upgradable - Ability to upgrade the system at any time by a adding wavelengths as a scanner
    • User friendly design - Touch screen and remote keypad, Dual Port for efficient setup of alternate delivery devices, advance memory settings
    • SureSpot™ Optics Technology - Sharply defined and evenly distributed power on the retina
  • Weight (lbs): 126 lb (57 kg)
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Lumenis InSight™ | Lumenis 1000 | LaserLink HS adapter for compatible convergent optics slit lamps | LaserLink Z adapter for Zeiss SL130 and 30SL slit lamps | Laser Indirect Ophthalmoscope (LIO) Endoprobe | Array™ LaserLink™
  • Slit Lamp: Inquire
  • Delivered Spot Size: 50 - 1000 µm with LaserLink Z or InSight
    50 - 500 µm with H/S LaserLink
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: 100-230 VAC ± 10% 50/60 Hz, <10 amps,="" single="" phase="" amps,="" single="">
  • Dimensions (W × H × D): 18 in (45 cm) x 42 in (105 cm) x 25 in (63 cm)
  • Number of Wavelengths: 532 nm Green, 577 nm Yellow, 659 nm Red
  • Treatment Pulse Durations: 0.01 to 3.0 seconds
  • Aim Beam: Contrasting color, adjustable intensity 635 nm nominal, <1.0 mw="">
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare or Get quote for selected.
GYC-500 Vixi Green Scan Laser Photocoagulator / GYC-500 Green Laser Photocoagulator
  • Features: Lightweight and compact design
    This multifunction laser is housed in a small console. The space-saving design allows portablility to virtually any room. The GYC-500 can be integrated into the NIDEK CV-30000, ophthalmic surgical system.

    5.7-inch color LCD with touchscreen control box
    An intuitive graphic user interface and easy-to-read touch screen color LCD allows quick and easy setup along with verification of the scan pattern and treatment parameters.

    Stable and reliable green laser
    The GYC-500 Vixi / GYC-500 ensures stable laser output by using a solid state laser. Two cooling fans in the console maintain the correct internal temperature.

    Multiple scan patterns (available for GYC-500 Vixi)
    Incorporating Vixi, scan delivery units, into the GYC-500 enables laser treatments with various scan patterns. There are 22 preprogrammed scan patterns to allow treatment of varying retinal pathologies. The GYC-500 Vixi enhances treatment efficiency and reduces patient chair time.

    Auto forward (available for GYC-500 Vixi)
    Once photocoagulation is completed in one region, the GYC-500 Vixi allows automated advancement to the next region for delivery of the next scan pattern during photocoagulation.

    Wide range of selectable delivery units
    Scan Delivery Unit
    ·Scan slit lamp delivery unit (NIDEK SL-2000/SL-1800)
    ·Scan attachable delivery unit (NIDEK SL-2000/SL-1800/SL-1600, ZEISS SL 130, ZEISS 30SL/M, HAAG 900BQ)

    Single Delivery Unit
    • Slit lamp delivery unit (NIDEK SL-2000/SL-1800)
    • Atachable delivery unit (NIDEK SL-2000/SL-1800/SL-1600, ZEISS SL 130, ZEISS 30SL/M, HAAG 900BQ)
    • BIO delivery unit (HEINE OMEGA 500, Keeler All Pupil II)
    • YAG laser combination delivery unit (NIDEK YC-200/YC-1800)
    • Endophotocoagulation delivery unit (ZEISS, LEICA)
  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare or Get quote for selected.
MC-500 Vixi Multicolor Scan Laser Photocoagulator / MC-500 Multicolor Laser Photocoagulator
  • Features: -Multicolor on modular architecture
    The MC-500 Vixi / MC-500 allows the selection of one, two, or three wavelengths among green, yellow, and red.

    -Multiple scan patterns
    The MC-500 Vixi has 22 preprogrammed scan patterns to allow treatment of varying retinal pathologies.

    -Auto forward
    Once photocoagulation is completed in one region, the MC-500 Vixi allows automated positioning of the scan pattern to the next region to undergo photocoagulation. This feature allows the surgeon to concentrate on focus adjustment.

    -LPM (Low Power Mode) for minimally invasive photocoagulation
    LPM (Low Power Mode) is a form of laser treatment that delivers reduced power to the retina. In LPM, the standard (yellow) laser treatment power is reduced by a specified ratio.
    To use the optional LPM, the MC-500 Vixi has to be equipped with the yellow laser. An additional software upgrade is required.

    -Practical and user-friendly features
    Intuitive graphic user interface and easy-to-read color LCD touch screen allows easy and quick setup and confirmation of the scan pattern and treatment parameters.

    -Delivery unit options
    Scan delivery unit
    ·Scan slit lamp delivery unit (NIDEK SL-2000/SL-1800)
    ·Scan attachable delivery unit (NIDEK SL-2000/SL-1800/SL-1600, ZEISS SL 130, HAAG 900BQ / 900BQ LED slit lamp)

    Single delivery unit
    · Slit lamp delivery unit (NIDEK SL-1800)
    · Attachable delivery unit (NIDEK SL-1800/SL-1600, ZEISS SL 130)
    · BIO delivery unit (HEINE OMEGA 500)
    · YAG laser combination delivery unit (NIDEK YC-1800)
    · Endophotocoagulation delivery unit (ZEISS, LEICA)

  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare or Get quote for selected.
YLC-500 Vixi Yellow Scan Laser Photocoagulator / YLC-500 Yellow Laser Photocoagulator
  • Features: -Stable and reliable yellow laser

    -Multiple scan patterns (only for YLC-500 Vixi)
    The YLC-500 Vixi has 22 preprogrammed scan patterns to allow treatment of varying retinal pathologies.

    -Auto forward (only for YLC-500 Vixi)
    Once photocoagulation is completed in one region, the auto forward function automatically positions the scan pattern to the next region of treatment, allowing the surgeon to concentrate on adjusting focus.

    -LPM* (Low Power Mode) for minimally invasive photocoagulation (only for YLC-500 Vixi)
    LPM is a form of laser photocoagulation that delivers reduced power to the retina for a therapeutic effect. During treatment, the standard (yellow) laser power is decreased by a specified ratio.
    *Optional software for YLC-500 Vixi only.
    Auto forward function
    Auto forward function allows automated positioning of the scan pattern for photocoagulation.
    Arcade grid scan pattern
    In addition to regular mode, LPM includes a scan pattern that prevents treatment in a central circular area within the grid.

    -User friendly features
    An intuitive graphic user interface and easy-to-read touch screen color LCD allow quick and easy setup and verification of the scan pattern and treatment parameters.

    -Wide range of selectable delivery units
    Scan delivery unit
    ·Scan slit lamp delivery unit (NIDEK SL-2000/SL-1800)
    ·Scan attachable delivery unit (NIDEK SL-2000/SL-1800/SL-1600, ZEISS SL 130, HAAG BQ900)
    Single delivery unit
    ·Slit lamp delivery unit (NIDEK SL-2000/SL-1800)
    ·Attachable delivery unit (NIDEK SL-2000/SL-1800/SL-1600, ZEISS SL 130)
    ·BIO delivery unit (HEINE OMEGA 500)
    ·Endophotocoagulation delivery unit (ZEISS, LEICA)

  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare for selected.
Easyret 577nm Fiber Technology Laser
  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Dimensions (W × H × D): Inquire
  • Aim Beam Power: Inquire
  • Graphical User Interface: Inquire
Read More
Inquire
Compare for selected.
VITRA 2 532nm Retinal Photocoagulation
  • Features: Vitra 2: Technology
    • New generation of laser cavity with an increased max power level
    • New "space saving" design including a large touch screen
    • Single Spot / MultiSpot scalability


    Vitra 2: All-new clinically oriented software
    • Easy to use user interface
    • Software guided treatment procedures
    • Printable treatment reports


    Vitra 2: Wide range of delivery systems
    • Slit lamp adapters compatible with Haag Streit and Zeiss types slit lamps
    • Slit lamp adapters compatible with Quantel Medical YAG and YAG/SLT lasers
    • Operating Microscopes, Laser indirect ophthalmoscopes and laser probes
  • Weight (lbs): 5.6 kg - 12.3 lbs
  • Portability: Yes
  • Power (V): 1500 mW (at tissue)
  • Delivery Systems: OR microscope adapters compatible with:
    • Zeiss type
    • Leica type

      Laser indirect ophthalmoscopes:
      • Heine Omega 500
      • Keeler Vantage Plus
      Laser Probes
      • Straight: 20, 23, 25 Gauge
      • Curved: 20 Gauge
      • Flexible curved: 23, 25 Gauge
      • Steerable: 23, 25 Gauge
      • Illuminated: 23, 25 Gauge
  • Slit Lamp: Slit lamp adaptability: Quantel Medical slit lamp, Haag Streit BM & BQ and clones, CSO SL 9800
    Lasers: Optimis 2 and Optimis Fusion
  • Delivered Spot Size: SingleSpot slit lamp adapters50 µm to 500 µm

    Multispot slit lamp adapter:
    • MonoSpot Mode: 50 µm to 400 µm
    • MultiSpot Mode: 100 µm to 400 µm
  • Laser Compatibility: Quantel Medical slit lamp, Haag Streit BM & BQ and clones, Zeiss 30 SL, 120 SL et 130 SL and clones, CSO SL 9800
  • Patterns: Square, circle, triple arcs, single spot
  • Power Input: 100 to 240 VAC, 250 VA, 50/60 Hz
  • Dimensions (W × H × D):
    • 18 cm (H) x 19.5 cm (W) x 30 cm (D)
    • 7.1" (H) x 7.7" (W) x 11.8" (D)
  • Number of Wavelengths: 1
  • Treatment Pulse Durations: 10 ms to continuous
  • Aim Beam: 635 - 650 nm
  • Aim Beam Power: Inquire
  • Retinal Spot Size: SingleSpot slit lamp adapters:50 µm to 500 µm

    Multispot slit lamp adapter:
    • MonoSpot Mode: 50 µm to 400 µm
    • MultiSpot Mode: 100 µm to 400 µm
  • Graphical User Interface: Inquire
Read More
Inquire
Compare or Get quote for selected.
Endpoint Management™ with Landmark Patterns™
  • Features:
    • Fine control of laser output to delivery visible or non-visible laser applications.
    • Ability to "Landmark" the treatment area to confirm laser delivery.
    • Available as an upgrade to existing PASCAL, Streamline and Streamline 577 laser systems.
  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Slit Lamp: Inquire
  • Delivered Spot Size: Inquire
  • Laser Compatibility: Inquire
  • Patterns: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Compare or Get quote for selected.
PASCAL Photocoagulator

PASCAL Photocoagulator

Topcon Medical Laser Systems

  • Features: Inquire
  • Weight (lbs): Inquire
  • Portability: Inquire
  • Power (V): Inquire
  • Power Control: Inquire
  • Delivery Systems: Inquire
  • Laser Compatibility: Inquire
  • Power Input: Inquire
  • Dimensions (W × H × D): Inquire
  • Number of Wavelengths: Inquire
  • Treatment Pulse Durations: Inquire
  • Aim Beam: Inquire
  • Aim Beam Power: Inquire
  • Retinal Spot Size: Inquire
  • Graphical User Interface: Inquire
Read More
Select up to 5 products from above to compare or request more information.