Capsular Tension Rings

CompanyFCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.
ItemEYEJET™ Capsular Tension Ring (CTR)Ahmed Capsular Tension Segments (CTS)Morcher® Capsular Tension RingsMorcher® Capsular Tension RingsMorcher® Cionni Capsular Tension Rings
Price
Catalog NumberInquireInquireMR-1400MR-1410MR - 1L
MR - 2L
MR - 2C
DescriptionThe EYEJET CTR consists of a disposable injector which is preloaded with one of the three Type 14 CTRs (14, 14A or 14C). Each preloaded injector is packaged in a peel-open, contoured container in which it has been sterilized and is ready for use. The Ahmed CTS is a modified design of the Cionni capsular tension rings manufactured by Morcher GmbH of Stuttgart, Germany. The CTS is a partial ring of clear PMMA covering approximately one quadrant with a hole for temporary or permanent fixation.Three CTR types have been approved: Type 14, 14A and 14C. The three rings are available in different diameters to accommodate the variations in the size of the individual patient’s capsular bag. Morcher capsular tension rings (CTR) are designed to Three CTR types have been approved: Type 14, 14A and 14C. The three rings are available in different diameters to accommodate the variations in the size of the individual patient’s capsular bag. Morcher capsular tension rings (CTR) are designed to Designed to stabilize the capsular bag in cases of damaged or missing zonules. The Cionni CTR is specially designed for scleral fixation with suture. Robert J. Cionni, M.D. of the Cincinnati Eye Institute, recognized from his early experience using
FeaturesInquireInquireAdvantages:
  • Circular expansion of capsular bag
  • Stable conditions during surgery
  • Improves IOL centration
  • Reduced risk of capsular fibrosis
  • Resists capsular shrinkage

Indications:

  • Missing or damaged zonules
  • Lens subluxation
  • Pseudoexfoliation
  • Myoplia
  • Zonulolysis
  • Soft IOL
  • Marfan's Syndrome
Advantages:
  • Circular expansion of capsular bag
  • Stable conditions during sergery
  • Improves IOL centration
  • Reduced risk of capsular fibrosis
  • Resists capsular shrinkage
Indications:
  • Missing or damaged zonules
  • Lens subluxation
  • Pseudoexfoliation
  • Myoplia
  • Zonulolysis
  • Soft IOL
  • Marfan's Syndrome
  • May be fixated to the sclera
  • Promotes circular expansion of the capsular bags
  • Stabilizes conditions during surgery
  • Improves IOL centration
  • Resists capsular shrinkage
  • MR-2C may be inserted with the Geuder injector #G-32955
ApprovalInquireUS FDAUS FDAUS FDAUS FDA
TypePreloaded Type 14 CTR
Preloaded Type 14A CTR
Preloaded Type 14C CTR
Inquire14, For Normal Eyes14A, For Highly Myopic EyesType 1L
Type 2L
Type 2C
Dimensions (mm)InquireInquire10 to 12.312 to 14.511mm
Radial CoverageInquireInquireInquireInquireInquire