Capsular Tension Rings

CompanyFCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.FCI Ophthalmics Inc.
ItemAhmed Capsular Tension Segments (CTS)EYEJET™ Capsular Tension Ring (CTR)Henderson Capsular Tension RingMorcher® Capsular Tension RingsMorcher® Capsular Tension Rings
Price
Vendor Product PageCompany Product Page
Catalog NumberInquireInquireMR-10CMR-1400MR-1410
DescriptionThe Ahmed CTS is a modified design of the Cionni capsular tension rings manufactured by Morcher GmbH of Stuttgart, Germany. The CTS is a partial ring of clear PMMA covering approximately one quadrant with a hole for temporary or permanent fixation.The EYEJET CTR consists of a disposable injector which is preloaded with one of the three Type 14 CTRs (14, 14A or 14C). Each preloaded injector is packaged in a peel-open, contoured container in which it has been sterilized and is ready for use. The Henderson Ring is a special design of the popular capsular tension rings (CTR) manufactured by Morcher GmbH of Stuttgart, Germany. The Henderson Ring is an open C-shaped loop made of a single piece of Polymethyl Methacrylate (PMMA). Employing Three CTR types have been approved: Type 14, 14A and 14C. The three rings are available in different diameters to accommodate the variations in the size of the individual patient’s capsular bag. Morcher capsular tension rings (CTR) are designed to Three CTR types have been approved: Type 14, 14A and 14C. The three rings are available in different diameters to accommodate the variations in the size of the individual patient’s capsular bag. Morcher capsular tension rings (CTR) are designed to
FeaturesInquireInquire
  • Circular expansion of capsular bags
  • Stablilizes conditions during surgery
  • Facilitates cortical removal
  • Improves IOL centration
  • Reduces risk of capsular fibrosis
  • Resists capsular shrinkage
Advantages:
  • Circular expansion of capsular bag
  • Stable conditions during surgery
  • Improves IOL centration
  • Reduced risk of capsular fibrosis
  • Resists capsular shrinkage

Indications:

  • Missing or damaged zonules
  • Lens subluxation
  • Pseudoexfoliation
  • Myoplia
  • Zonulolysis
  • Soft IOL
  • Marfan's Syndrome
Advantages:
  • Circular expansion of capsular bag
  • Stable conditions during sergery
  • Improves IOL centration
  • Reduced risk of capsular fibrosis
  • Resists capsular shrinkage
Indications:
  • Missing or damaged zonules
  • Lens subluxation
  • Pseudoexfoliation
  • Myoplia
  • Zonulolysis
  • Soft IOL
  • Marfan's Syndrome
ApprovalUS FDAInquireFDAUS FDAUS FDA
TypeInquirePreloaded Type 14 CTR
Preloaded Type 14A CTR
Preloaded Type 14C CTR
10C HCTR14, For Normal Eyes14A, For Highly Myopic Eyes
Dimensions (mm)InquireInquireInquire10 to 12.312 to 14.5
Radial CoverageInquireInquireInquireInquireInquire
Get quote