BD Visitec™ Anterior Chamber Maintainer Micro Etched [Dahan]
  • Description: Special micro-etching on tip allows ACM to be self-retaining. Ultra thinwall tip provides high flow rate.

    Dimension: .90mm x 4.0mm
    Tip: Beveled 45°
    Tubing: Flexible 15.25cm, ID - .75mm; OD - 1.6.0mm

  • Gauge: 20
Read More
Inquire
Compare for selected.
BD Visitec™ Bimanual Aspiration Cannula

BD Visitec™ Bimanual Aspiration Cannula

Beaver-Visitec International

  • Description: Curved 45° with a .40mm top aspiration port. Micro-etched 2.0mm from end. Facilitates removal of cortical debris between 10-2 o'clock, also useful for capsule polishing.

    Angle: 45°
    Port: .40mm top aspiration port

  • Gauge: 23
Read More
Inquire
Compare for selected.
BD Visitec™ Bimanual Irrigation Cannula

BD Visitec™ Bimanual Irrigation Cannula

Beaver-Visitec International

  • Description: Curved 45° with a .51mm open-end irrigation port. Facilitates removal of cortical debris between 10-2 o'clock.

    Angle: 45°
    Port: .51mm open end irrigation port

  • Gauge: 21
Read More
Inquire
Compare for selected.
BD Visitec™ Bishop Harmon Cannula

BD Visitec™ Bishop Harmon Cannula

Beaver-Visitec International

  • Description: Angled 40°, 8mm from end.

    Dimension: 1.1 x 25.0mm (19G x 1 in)

  • Gauge: 1.10mm (19 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Coaxial I and A Cannula (Modified) [Pierce]
  • Description: .80mm (21G) inner Cannula is angled 30° with a 30mm aspiration port
  • Gauge: I and A: 1.2mm (18G) thinwall outer Cannula; .80mm (21 G ) inner Cannula
Read More
Inquire
Compare for selected.
BD Visitec™ Coaxial I and A Cannula [Pearce]

BD Visitec™ Coaxial I and A Cannula [Pearce]

Beaver-Visitec International

  • Description: Inner Cannula has .30mm side aspiration port
  • Gauge: I and A: 1.2mm (18G) thinwall outer Cannula; .80mm (21 G ) inner Cannula
Read More
Inquire
Compare for selected.
BD Visitec™ Irrigation and Aspiration Cannula (Reverse) [Simcoe]
  • Description: Simcoe Reverse I & A, .30mm aspiration port. Plastic hubs designed & priced for single use.

    Dimension: .60mm/.60mm (23 G /23 G )
    Port: .30mm
    Tubing: ID-1mm (.04 in); OD -2.0mm (.08 in), 25cm (10 in) long

  • Gauge: .60mm (23 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Irrigation and Aspiration Cannula [Gills]
  • Description: Separate irrigation and aspiiration cannulas insert through two opposing side port incisions or side port and phaco incisions.
  • Gauge: I and A: .60 mm/.50 mm (23G/25G) thinwall, angled 35°, 8 mm from end, .25 mm open end aspiration port
Read More
Inquire
Compare for selected.
BD Visitec™ Irrigation and Aspiration Cannula [Simcoe]
  • Description: Simcoe I & A .30mm aspiration port.

    I and A: .60mm/.60mm (23 G /23 G ) thinwall Cannula
    Port: .30mm
    Tubing: ID-1.0mm (.04 in); OD -2.0mm (.08 in), 25cm (10 in) long

  • Gauge: .60mm (23 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Irrigation and Aspiration Cannula [Simcoe]
  • Description: Simcoe I & A .40mm aspiration port

    Dimension: 60mm/.60mm (23 G /23 G ) thinwall Cannula
    Port: .40mm
    Tubing: ID-1.0mm (.04 in); OD -2.0mm (.08 in), 25cm (10 in) long

  • Gauge: .60mm (23 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Irrigation and Aspiration Cannulas
  • Description: Separate irrigation and aspiiration cannulas insert through two opposing side port incisions or side port and phaco incisions.
  • Gauge: I and A: .80 mm/.80 mm (21G/21G), .50 mm open end aspiration port
Read More
Inquire
Compare for selected.
BD Visitec™ LASIK Irrigation Cannula [Lindstrom]
  • Description: Used after ablation to wash away particulate from anterior & posterior sides of flap & stromal bed. Features three .25mm ports located on 7mm extension with a 11mm radius, angled 45°.

    Dimension: .50 x 22.0mm (25 G x 7/8 in)

  • Gauge: .50mm (25 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Olive Tip Cannula

BD Visitec™ Olive Tip Cannula

Beaver-Visitec International

  • Description: Olive shape tip is 2.0mm long x 1.0mm wide with a .33mm end port.

    Dimension:.60mm x 22.0mm (23 G x 7/8 in)

  • Gauge: .60mm (23 G)
Read More
Inquire
Compare for selected.
BD Visitec™ Oval Anterior Chamber Maintainer [Blumenthal]
  • Description: Oval shape and smooth tip allow for easy insertion and minimal tissue disturbance.

    Dimension: Tapered from 1.25mm to .90mm oval, 3.5mm
    Tip: Beveled 40°
    Tubing: Flexible 25cm, ID - 1.0mm; OD - 2.0mm

  • Gauge: Tapered from 18 G to 20 G oval
Read More
Inquire
Compare for selected.
BD Visitec™ Self Retaining Anterior Chamber Maintainer [Lewicky]
  • Description: Unique annular rings start .85mm from 55° beveled tip for retaining without sutures

    Dimension: .90mm x 3.5mm
    Tip: 55° Bevel
    Tubing: Flexible 25cm, ID - 1mm; OD - 2mm

  • Gauge: 20
Read More
Inquire