Optical Pachymetry / Optical Pachycam

Optical pachymetry is the process in which an eye doctor measures the thickness of a patient's cornea. A device called a pachymeter is used to get the measurements needed, which can be used prior to certain eye surgeries — such as refractive surgery — or also to look for signs of glaucoma. Pachymeters are non-invasive and many of today's devices use the latest technologies to ensure very accurate measurements.
CompanyOCULUS, Inc.OCULUS, Inc.
ItemOCULUS Pentacam® HROCULUS PARK 1®
Price
Vendor Product PageCompany Product PageCompany Product Page
DescriptionThe Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total The PARK1® combines a non-contact pachymeter, auto-refractometer and keratometer in one unit. In addition to the objective refraction, the keratometer values and the pachymetry can be determined with precision in a matter of seconds with the PARK 1®.
Features
  • High resolution cross sectional images of the anterior segment
  • Axial and tangential topography maps
  • Total corneal refractive power
  • Pachymetry maps
  • Anterior and posterior corneal elevation maps
  • Zernike corneal wavefront analysis
  • Anterior chamber angle measurement
  • Anterior chamber depth and volume measurements
  • 3D Lens Densitometry and Pentacam Nucleus Staging (automatic classification of lens opacity)
  • Corneal Optical Densitometry for assessing and quantifying corneal opacification
  • Fast Screening Report to quickly identifying abnormalities found in common pathologies
  • Cataract Pre-op Display for premium IOLs
  • Holladay Report with equivilent K readings
  • Keratoconus detection and staging
  • Belin/Ambrosio Enhanced Ectasia
  • Contact Lens Fitting with simulated fluorescein image
  • Various comparison displays including Compare 2 Scheimpflug
  • Network ready - Up to 50 workstations included
    Optional Features:
  • PIOL Fitting Software
  • DICOM Interface
One quick measurement delivers:
  • refraction
  • central K-readings
  • non-contact pachymetry on a 4 mm slice
  • thinnest spot
  • IOP correction
ApprovalUS FDAUS FDA
InterfaceUSB, DICOM compatibleInquire
DisplayThe Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities. Standard Software: Belin/Ambrosio Enhanced Ecstasia, Holladay Report, Contact Lens Fitting, Cataract package and Refractive Package.Inquire
Optical PachymetryInquireThe optional, non-contact pachymetry is based on Scheimpflug images and makes precise non-contact measurement of the corneal thickness possible. - Measurement of the corneal thickness in the apex and the minimum corneal thickness in the entire measuring area - Measurement of 600 absolute height values on a horizontal 4 mm cut through the apex - Presentation of the corneal thickness profile in the form of a diagram. Automatic adjustment of the scaling of the Pachymetry measurements for better presentation of the individual thicknesses - Pachymetry-based correction of the separately measured intraocular pressure