Ultrasound technology can help probe the human eye without causing damage to this delicate organ, and so its use in ophthalmology is constantly expanding. Ultrasonic pachymeters (or pachometers) allow the surgeon or general ophthalmologist to measure the thickness of the cornea in patients with glaucoma, suspected hypertension or those considering refractive surgery. One primary advantage of an ultrasonic pachymeter is how cost-effective it can be as compared to alternatives such as confocal microscopy. These pachymeters are generally hand-held. In addition to corneal thickness, the customer should seek capabilities like pre-programed formulas for intraocular lenses (IOL) and post-refractive surgery.

Get quotes for all products
Select up to 5 products from below to compare or request more information.
Compare or Get quote for selected.
DGH Pachette 3 Ultrasonic Pachymeter
  • Features:
    • IOP Correction Calculation
    • Backlit LCD character displays OD and OS measurements
    • Weighs only 0 .8 kilograms
    • Measuring and storing up to 25 measurements bilaterally in as little as 1.6 seconds per eye
  • Probe Frequency: Inquire
  • Biometry Measurement: Inquire
Read More
Compare or Get quote for selected.
DGH-550 PACHETTE 2

DGH-550 PACHETTE 2

DGH Technology, Inc.

  • Features:
    • Simple to use. Turn on power and the Pachette 2 is ready to take measurements.
    • Automatic measurement mode for operation without a foot switch.
    • Obtains multiple measurements very rapidly at a single location.
    • Simultaneously displays the current measurement and the average of all measurements taken.
    • A single applanation automatically stores up to 50 measurements.
    • Large 16 x 2 LCD character display allows easy visibility from a distance over a large viewing angle and in all lighting conditions.
  • Probe Frequency: Inquire
  • Biometry Measurement: Accuracy: ± 5 microns
    Resolution: 1 micron
Read More
Compare or Get quote for selected.
Pachmate DGH55

Pachmate DGH55

DGH Technology, Inc.

  • Features:
    • Measurement Range:
    • Standard: 200 microns to 1100 microns
    • Flap Option: 95 microns to 1100 microns
    • Accuracy: ± 5 microns
    • Resolution: 1 micron
    • Internal Clock Accuracy: ±0.002%
    • Size: Length 6.92" (175 mm) x Width 1.69" (43 mm) Depth .83” (21 mm)
    • Weight: 3.6 Ounces (112 grams)
    • Power Requirement: Two (2) AAA batteries
  • Probe Frequency: Inquire
  • Biometry Measurement: Accuracy: ± 5 microns Resolution: 1 micron
Read More
Compare or Get quote for selected.
ODM-1000A/P Ultrasonic Biometer/Pachymeter
  • Features:
    • Automatic and manual gain control modes
    • Immersion Mode measurement
    • Live waveform display
    • Multi-modes measurements
    • Eight groups of measurements to calculate IOL.
    • Portable and sleek.
    • Stores up to 25 measurements by cornea location
    • Build-in thermal printer
      A-Biometer:
    • Gain ≥90dB
    • Gain changeable for users: 0-32dB
    • Accuracy: ≤0.06mm
    • Measure Range: 15-39mm
    • Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
    • Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
      Pachymeter:
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Probe Frequency: Pachymeter: 20MHz
  • Biometry Measurement: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
Read More
Compare or Get quote for selected.
ODM-1000P Pachymeter

ODM-1000P Pachymeter

MEDA CO., LTD.

  • Features:
    • Stores up to 25 measurements by cornea location
    • Central and Peripheral cornea map
    • Build-in thermal printer
    • Accurate and Reliable
    • Portable and sleek
      Pachymeter
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Probe Frequency: 20MHz
  • Biometry Measurement: Inquire
Read More
Compare or Get quote for selected.
Ultrasound US-4000/500
  • Features:
    • Accurate axial-length and corneal-thickness measurements in either automatic or manual modes
    • Available in a single configuration or in combination with the A scan, for maximum cost efficiency
    • Extremely fast biometry measurement
    • Accurate pacymetry measurement
    • No PC required
    • Tiltable color LCD touch-screen monitor
  • Probe Frequency: Inquire
  • Biometry Measurement: Inquire
Read More
Compare or Get quote for selected.
Compact Touch 3 in 1 Ultrasound System
  • Features:
    • The performance in a compact system: no PC required, colour and touch screen, only 9.4 lbs (4.2 kg), easy data transfer to EMR/network, 2 USB + 2 PS2 +1 ethernet port.
    • B-Scan: automatic recording with Cineloop, adjustable gain on frozen pictures, post processing tools, user friendly software with unlimited data base.
    • Biometry option: 6 IOL formulas, 6 post-refractive formulas, scleral echo discrimination to eliminate optic nerve scans, a specific and customizable mode for patients with silicon in vitreous.
    • Pachymetry option: multiple corneal maps with graphical displays, adjustable corneal velocity, 4 measuring modes.
    • Biometry in B mode: Especially useful on patients with high myopia, or posterior staphyloma. The cross vector is positioned along the visual axis of a B-Scan image. The axial length is automatically measured and transferred into biometry software for immediate IOL calculation.
    • ProBeam option: Biometry probe with built-in laser pointer, projects a luminous fixation point on the wall or ceiling. When focusing on this point with the opposite eye, the A-Scan beam is automatically focused on the patient’s visual axis for even faster scans.
  • Probe Frequency: B probe: 10 MHz, A probe: 11 MHz, Pachymetry probe: 20 MHz
  • Biometry Measurement: Inquire
Read More
Compare or Get quote for selected.
Pocket II Precision Pachymeter

Pocket II Precision Pachymeter

Quantel Medical, Inc.

  • Features:
    • Portable Precision: Weighs only 16 oz (460 gr) and measures with accuracy +/- 5 microns. The POCKET II Precision Pachymeter is about 8" X 4" x 2" and really does fit in a lab coat pocket or briefcase.
    • Versatile: User programmable for refractive surgery and difficult-to-measure corneas where pathology can be present.
    • Perfect for Glaucoma Screening: Dedicated software for glaucoma that also complies with all your pachymetry needs.
    • Verify Accuracy: Built-in test block - eliminates lost test blocks.
    • Battery Powered: Powered by 4 AA batteries. You can take it to the operating room or your remote clinic.
    • Computer printout: The Pocket Pachymeter connects to a standard computer printer and provides a full size printed record.
  • Probe Frequency: 20 MHz
  • Biometry Measurement: Corneal thickness, accuracy +/- 5 microns
Read More
Compare for selected.
Corneo-Gage™ Plus

Corneo-Gage™ Plus

Sonogage, Inc.

  • Features:
    • Completely Portable-move it from lane to lane, office to office
    • No foot pedal, no power cord
    • Battery level indicator
    • Easy To Use-ergonomic probe with continuous read mode
    • Provides Repeatable Readings of the Highest Accuracy
    • Measures the corneal epithelium- optional mode
    • Exclusive 50 MHz solid state transducer
    • Each individual reading is the average of 1000 ultrasonic echoes
    • Individual readings are not averaged-false high values cannot be obtained
    • Automatic calibration verification
    • Built-in dot matrix printer available
    • Built-in IOP correction chart for glaucoma and hypertension patients-optional
  • Probe Frequency: 50 MHz
  • Biometry Measurement: accurate reproducible corneal thickness measurements