A digital fundus camera is used to take an image of the fundus — the back portion of the eye that includes the retina, macula, fovea, optic disc and posterior pole. A digital fundus camera normally consists of a camera with a specialized microscope attached. Either a lamp or flash provides the light necessary for photo taking, and depending on the camera photos at different angles of view — from narrow to wide — can be taken. The resulting image can then be used by an ophthalmologist for diagnosis and treatment.
Get quotes for all products
Select up to 5 products from below to compare or request more information.
Featured products
- Features: Non-mydriatic retinal images with 40 degrees field of view. Peripheral imaging using external fixation. Images both anterior and posterior segments. Low Power LED light source for image capture. Focus assistance for optimal image clarity.
- Weight (lbs): 22lbs (10kg)
- Pupil Diameter: 3.0 mm
- Power Source: Input: AC 100-240V, 50/60 Hz
Output: for DC power adapter 5V/4A’ with ‘5V/4A for DC power adaptor - Working Distance: Inquire
- Field Angle/Angle of View: 40 degrees
- Light Source: LED
- Digital Resolution: Inquire
- Camera: 3 mega-pixel, 8 - 14 microns
- Monitor: On labtop
- Power Consumption: 5 to 10 watts
- Fixation Targets: Manual
- Database: Inquire
- Dimensions (W × H × D): (WxDxH) 13 x 19 x 24 inches
- Refractive Error Compensation: No
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features: The ultimate multimodal imaging platform
For the SLO/OCT model
- Color / FA / ICG / Blue-FAF / Green-FAF / Retro mode
- OCT / OCT-Angiography*
For the SLO model
- Color / FA* / ICG* / Blue-FAF /Green-FAF / Retro mode
* Optional
Streamlined combination capture
The Combo image capture allows sequential capture of images with the preset combination of image capture settings for each specified disease.
Ultra wide field x ultra HD image
A stellar combination of 163°ultra wide field x ultra 4K HD incorporated in the Mirante achieves a wider, enhanced view of the retinal structure and vasculature with unparalleled clarity.
(Angle of view is measured from the center of the eye. Ultra wide field image is available with the optional wide-field adapter.)
Unsurpassed color
Three separate RGB detectors simultaneously scan different depths of the retina with red, green, and blue wavelengths, producing unsurpassed color and allowing fine adjustment of the histogram.
Dynamic/Simultaneous FA and ICG
Dynamic blood flow using FA and ICG can be recorded with the Mirante. It also allows simple, simultaneous acquisition of FA and ICG images.
Unique Retro mode
The unique Retro mode modality is a non-invasive technique for visualizing pathologies deeper than the retinal pigment epithelium and detecting pathologic changes in the choroid. The pseudo-3D images from Retro mode allow better clinical appreciation of the extent of the pathology.
HD wide area OCT
High definition OCT images can be acquired for a maximum 16.5 x 12 mm area, allowing a wide, detailed assessment from the vitreous to choroid in a single shot. The Mirante SLO/OCT also offers options for AngioScan OCT-Angiography and an anterior segment OCT adapter.
Fly Through function
The Fly Through function further enhances multimodal imaging by registering and synchronizing images from different modalities to view the same area while scrolling through the region of interest. - Weight (lbs): Inquire
- Pupil Diameter: Inquire
- Power Source: Inquire
- Working Distance: Inquire
- Field Angle/Angle of View: Inquire
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: Inquire
- Dimensions (W × H × D): Inquire
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features:
- Robotic Fundus camera
- Enhanced Image Quality with 12MP Sensor
- Small Pupil Photography, ɸ2.0mm or More
- Rapid and Simple Capture by Single Touch
- Multiple Connectivity Options
- 50° Field of View
- Stereoscopic Photography
- Bilateral 2-Field Photography
- Weight (lbs): 20 kg (44.1 lb)
- Pupil Diameter: Inquire
- Power Source: Source voltage: AC100 to 240V;
Power input: 70 to 120VA;
Frequency: 50 to 60Hz
- Working Distance: 35.5mm (1.4in)
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: Inquire
- Dimensions (W × H × D): 332-426mm (13.1-16.8in)(W) x 519-769mm (20.4-30.3in)(H) x 540-680mm (21.3-26.8in)(D)
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features: Quickly & effortlessly capture fundus images for visualization & patient education. Facilitate doctor-patient discussions related to disease progression and treatment plan. Free mobile application available in the Apple App Store* (search Volk iNview).
- Weight (lbs): 0.71 lbs/325g; 0.91 lbs/413g with iPod Touch
- Pupil Diameter: Inquire
- Power Source: Internal electronic camera device battery
- Working Distance: 50mm
- Field Angle/Angle of View: 50° / 80°
- Light Source: LED
- Digital Resolution: 918 x918 Pixels (843 Kpixels total, 466 Kpixel retina area)
- Camera: iPhone iSight Camera (5s, 6, 6s, SE) 8 Mp or 12 MP
- Monitor: iPhone
- Power Consumption: 5 VDC Output (iPhone)
- Fixation Targets: Not Included
- Database: Inquire
- Dimensions (W × H × D): 94mm x 180mm x (variable 134mm - 149mm)
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
Inquire
Heidelberg Engineering, Inc.
- Weight (lbs): Inquire
- Pupil Diameter: ≥ 2.5 mm
- Power Source: Inquire
- Working Distance: Inquire
- Field Angle/Angle of View: Inquire
- Light Source: 820 nm laser; 870 nm SLD
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: HEYEX Software platform
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
Inquire
- Features: Inquire
- Weight (lbs): Inquire
- Pupil Diameter: Inquire
- Power Source: Inquire
- Working Distance: Inquire
- Field Angle/Angle of View: Inquire
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: Inquire
- Dimensions (W × H × D): Inquire
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features: Inquire
- Weight (lbs): 46 lbs (21kg) (Excluding Attached SLR Camera)
- Pupil Diameter: Normal Mode: ?4.0mm
SP Mode:?3.5mm
Stereo Mode: ?4.0mm - Power Source: Input: AC100-240V 50/60Hz Power Consumption: 150VA
- Working Distance: 30mm
- Field Angle/Angle of View: Inquire
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Specific Nikon® Digital SLR Camera
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Internal: Central, Disc, Macula, mosaic 8 positions
External: Red light (option) - Database: Inquire
- Dimensions (W × H × D): 310 mm x 548 mm x 504 mm
- Refractive Error Compensation: Without Compensation: -12D to +13D
-Compensation: -32D to -10D
+Compensation: +10D to +35D - Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: 55mm (Electric)
Read More
- Features:
- Mydriatic & Non-mydriatic operation
- Colour & FA modes
- Optional FAF mode
- Clear view finder & LCD alignment
- Small pupil mode
- 50° and 30° views
- Weight (lbs): 78lbs (35.5kg) without video adapter
- Pupil Diameter: Non-mydriatic mode: Ø4.0mm
Mydriatic mode: Ø5.5mm (SP mode: Ø4.0mm) - Power Source: Inquire
- Working Distance: 39mm (between objective lens and cornea)
- Field Angle/Angle of View: Inquire
- Light Source: For observation : Halogen Lamp
For photography : Xenon flash lamp - Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Internal: 4 fixed dots right or left eye switching (Non-Mydriatic mode)
External: Red / green, blinking - Database: Inquire
- Dimensions (W × H × D): 400 mm x 620 mm x 520
- Refractive Error Compensation: Without compensation : -12D to + 13D
Compensation – : –32D to - 10D
Compensation + : +10D to +35D - Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features:
- 7 in 1 Hybrid retinal imaging system (FAF, FA, RF, Colour, Non-Mydriatic, Auto Mosaic and Anterior picture)
- Supports diagnosis of ARMD
- Dual magnification split (50° & 30° views)
- Complete pan and tilt capability
- Simple, easy to use with built-in PC
- Ergonomic design
- Seamless network connections
- Direct print capability
- Weight (lbs): 86lbs (39kg)
- Pupil Diameter: Non-mydriatic mode: Ø4.0mm (SP mode: Ø3.5mm)
Mydriatic mode: Ø5.5mm (SP 1 mode: Ø4.0mm, SP2 mode: Ø3.5mm) - Power Source: Input : AC 120/230V 50/60Hz Power consumption : 250 VA 1500 VA (max.)
- Working Distance: 39mm (Between the examined eye and the object lens)
- Field Angle/Angle of View: Non-mydriatic mode: 45°/27°
Mydriatic mode: 50°/ 30° (SP: 45°/27°) - Light Source: For observation : Halogen Lamp For photography : Xenon flash lamp
- Digital Resolution: Inquire
- Camera: Higher than 12 megapixel CMOS sensor
- Monitor: 7 inch wide-screen touch LCD
- Power Consumption: Inquire
- Fixation Targets: Internal: Central/disc/macular/peripheral
External: red/green LED - Database: Inquire
- Dimensions (W × H × D): 390 mmc x 540 mmc x 720 mmc
- Refractive Error Compensation: Without compensation : -12D to + 13D
Compensation – : –32D to - 10D
Compensation + : +10D to +35D - Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features: -All in one with built-in camera and computer
-Five automated functions for enhanced ease-of-use - 3-D auto tracking
- Auto focus
- Auto switching from anterior eye to fundus
- Auto shot
- Auto print / export
-Monitor and indicator for operator assist
The anterior eye monitor allows an operator to constantly verify alignment. The focus split indicator shows the amount of focus deviation in the fundus observation screen.
-Navigation of stereo and panorama photography
-Low flash intensity and quiet shutter sound - Weight (lbs): Inquire
- Pupil Diameter: Inquire
- Power Source: Inquire
- Working Distance: Inquire
- Field Angle/Angle of View: Inquire
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: Inquire
- Dimensions (W × H × D): Inquire
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features: Fundus image acquisition with macula and disc capture in one image on OCT
Combined diagnosis of macular and disc pathologies
A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot.
The normative database (macula: 9 x 9 mm, disc: 6 x 6 mm) provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.
B-scan image denoising using deep learning
A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort.
Fundus autofluorescence (FAF)
The FAF function is an advanced screening feature that allows non-invasive evaluation of the RPE without contrast dye.
Optional features
-AngioScan
-Long axial length normative database
-Anterior segment adapter
- Weight (lbs): Inquire
- Pupil Diameter: Inquire
- Power Source: Inquire
- Working Distance: Inquire
- Field Angle/Angle of View: Inquire
- Light Source: Inquire
- Digital Resolution: Inquire
- Camera: Inquire
- Monitor: Inquire
- Power Consumption: Inquire
- Fixation Targets: Inquire
- Database: Inquire
- Dimensions (W × H × D): Inquire
- Refractive Error Compensation: Inquire
- Base Horizontal Movement: Inquire
- Base Vertical Movement: Inquire
- Chinrest Movement: Inquire
Read More
- Features:
- Color fundus, red-free, and fluorescein, (ICG and auto-fluorescence are available)
- Can support a variety of photo devices, from film to high resolution digital cameras
- Easy-to-use touch-screen control panel
- 50°, 35°, and 20° angles of coverage
- Small pupil mode and aperture adjustment
- 21 levels of flash intensity
- Comfortable backlit panel for use in darkened environments
- Working distance dots
Weight (lbs): InquirePupil Diameter: InquirePower Source: InquireWorking Distance: 39mm [1.5 in.]Field Angle/Angle of View: InquireLight Source: InquireDigital Resolution: InquireCamera: InquireMonitor: InquirePower Consumption: InquireFixation Targets: InquireDatabase: InquireDimensions (W × H × D): InquireRefractive Error Compensation: InquireBase Horizontal Movement: InquireBase Vertical Movement: InquireChinrest Movement: Inquire
Read More
- Features:
- Versatile and economical full function imaging system with color, red free and FA capabilities
- Auto focus and auto capture
- Intelligent software prevents mistakes and insures correct capturing in any mode
- Tri-functional fully digital retinal camera
- 12.3 megapixel resolution
- Optical red-free function
- 9 internal fixation targets for image consistency when composing wide-field views
Weight (lbs): InquirePupil Diameter: InquirePower Source: InquireWorking Distance: InquireField Angle/Angle of View: InquireLight Source: InquireDigital Resolution: InquireCamera: InquireMonitor: InquirePower Consumption: InquireFixation Targets: InquireDatabase: InquireDimensions (W × H × D): InquireRefractive Error Compensation: InquireBase Horizontal Movement: InquireBase Vertical Movement: InquireChinrest Movement: Inquire
Read More
- Features:
- Versatile and economical full function retinal camera with color, red free and FA capabilities
- Auto focus and auto capture
- Intelligent software prevents mistakes and insures correct capturing in any mode
- Tri-functional fully digital retinal camera
- 12.3 megapixel resolution
- Optical red-free function
- 9 internal fixation targets for image consistency when composing wide-field views
- 45 years of experience in manufacturing retinal cameras
Weight (lbs): InquirePupil Diameter: InquirePower Source: InquireWorking Distance: 40.7 mmField Angle/Angle of View: InquireLight Source: InquireDigital Resolution: InquireCamera: InquireMonitor: InquirePower Consumption: InquireFixation Targets: InquireDatabase: InquireDimensions (W × H × D): InquireRefractive Error Compensation: InquireBase Horizontal Movement: InquireBase Vertical Movement: InquireChinrest Movement: Inquire
Read More
- Features:
- Maximum Portability - Lightweight and portable, Pictor is easily used between rooms and outside the office to examine convalescing patients and for geriatric or pediatric care.
- Simple Integration - Pictor is easily adopted into daily examination routines, connecting to any patient database system for fluent image data storage and sharing.
- Improved Patient Care - Digital still and video images created with Pictor provide accurate first diagnosis and planning for consistent follow up treatment.
- Modular - Two key ophthalmic attachments provide simple way to switch between posterior and anterior imaging.
Weight (lbs): InquirePupil Diameter: InquirePower Source: InquireWorking Distance: InquireField Angle/Angle of View: InquireLight Source: InquireDigital Resolution: InquireCamera: InquireMonitor: InquirePower Consumption: InquireFixation Targets: InquireDatabase: InquireDimensions (W × H × D): InquireRefractive Error Compensation: InquireBase Horizontal Movement: InquireBase Vertical Movement: InquireChinrest Movement: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags