Retinal Photocoagulation Laser

Retinal Photocoagulation Lasers are used to treat a variety of eye diseases including the two leading causes of blindness in the United States: Diabetic Retinopathy and Age-related Macular Degeneration. This precision laser can lower the risk of vision loss by cauterizing ocular blood vessels. Two types of Photocoagulation Lasers are used for conditions like Diabetic Retinopathy. The first is Focal Photocoagulation, which treats specific leaking blood vessels in the retina. The second is Scatter or Pan-retinal Photocoagulation; this type is used for more widespread damage over the retina. The risk of using a Retinal Photocoagulation Laser are low and side affects are rarely severe. Retinal Photocoagulation Lasers are often combined with other lasers to encompass a multitude of Ophthalmological surgical procedures. Deciding on which Retinal Photocoagulation Laser or combination laser for your practice depends on practice size, common procedures, patient dynamics as well as monetary investment.
CompanyIRIDEXIRIDEXIRIDEXIRIDEXIRIDEX
ItemIRIDEX OcuLight GL/GLx Green (532 nm) Laser FamilyIQ 532 ™ Laser SystemIRIDEX IQ 577™ Retina Laser SystemOcuLight TX 532 nm LaserTxCell™ Scanning Laser Delivery System
Price
DescriptionThe OcuLight® family of green laser photocoagulators includes the OcuLight GL and the OcuLight GLx models. Using the latest in solid-state technology, these lasers emit true continuous-wave (TrueCW™) green light at 532 nm. Patented solid-state The IQ 532™ Laser System from IRIDEX is a dual-port green laser for comprehensive ophthalmology. The device offers repeatable MicroPulse Laser Trabeculoplasty (MLT) for glaucoma therapy and Fovea-Friendly™ MicroPulse Laser Therapy1 for retinal The IQ 577™ is a state-of-the-art, 577 nm true yellow retina laser system, in a solid-state platform. This system also incorporates IRIDEX MicroPulse™ technology to offer physicians new treatment options for fine control and tissue-sparing proceduresThe OcuLight® Tx Green 532nm Laser is designed with higher power for conventional ophthalmic and otolaryngological procedures. Combining high power with high speed, the device offers superb efficiency with a full 2500 mW of deliverable laser energy. The TxCell™ Scanning Laser Delivery System from IRIDEX offers high versatility for higher volume. The TxCell Scanning Slit Lamp Adapter is coupled to the IRIDEX IQ 532™ or IQ 577™ laser, adding multiple modalities for treatment of glaucoma and
Features
  • Includes TrueCW™ laser pulses for maximum control and precision
  • Designed for durability, with a thermal management system to increase laser conversion efficiency and reliability
  • Enhances user interface with conveniently located, easily understood controls
  • Allows easy transport between rooms and offices
  • Repeatable MicroPulse Laser Trabeculoplasty (MLT) for glaucoma therapy
  • Fovea-Friendly™ MicroPulse Laser Therapy1 for retinal disorders Standard photocoagulation
  • TxCell™ Scanning Laser Delivery Device: multi-spot pattern scanning for efficient retinal photocoagulation
  • Efficient setup for LIO with dual port and wireless footswitch
  • True yellow, 577 nm wavelength for peak absorption in oxygenated hemoglobin
  • Patented MicroPulse technology for Fovea-friendly™ MicroPulse Laser Therapy for retinal disorders, and repeatable MicroPulse Laser Trabeculoplasty for glaucoma therapy
  • DualSense™ provides quick and simple selection of multiple delivery devices for RFID and SMA
  • Voice confirmation to aid surgical techniques
  • Intuitive graphical touch screen interface with high contrast color display
  • Includes TrueCW™ laser pulses for maximum control and precision
  • Designed for durability, with a thermal management system to increase laser conversion efficiency and reliability
  • Enhances user interface with conveniently located, easily understood controls
  • Allows easy transport between rooms and offices
  • Multi-spot pattern scanning for efficient retinal photocoagulation
  • Standard coagulation with optimized wavelengths: IQ 532™ or true-yellow IQ 577™ lasers
  • Confluent laser patterns for tissue-sparing1 MicroPulse™ protocols
  • Compatible with IRIDEX, Haag-Streit and Zeiss style slit lamps
ApprovalInquireInquireUS FDAInquireInquire
Product NumberGL
GLX
InquireIQ577InquireInquire
Weight (lbs)13.2 lbs (<6.0 kg)>19.2 lb (9.0 kg)19.2 lb (9.0 kg)13.2 lbs (<6.0 kg)>Inquire
Slit LampInquireInquireInquireInquireIRIDEX SL 980, IRIDEX SL 990, Zeiss 30SL, Zeiss SL 130, Haag-Streit BM/BQ 900 and equivalents
Delivered Spot SizeInquireInquireInquireInquireSingle spot: 50 µm, 100 µm, 200 µm, 300 µm, 500 µm
Multi-spot: 100 µm, 200 µm, 300 µm, 500 µm
Laser CompatibilityInquireInquireInquireInquireIQ 532™ (532 nm, Green) or IQ 577™ (577 nm, Yellow)
PatternsInquireInquireInquireInquireGrid (2x2 - 7x7), Circle, Triple Arc
Spacing: Confluent (zero), 1-, 2-, 3-spot spacing in 0.25 diameter increments
Power Input100–240 VAC, 50/60 HzInquire100-240 VAC, 50/60 Hz100–240 VAC, 50/60 HzInquire
Dimensions (W × H × D)12 in (30 cm) x 6 in (15 cm) x 12 in (30 cm)12 in (30 cm) x 8.5 in (21 cm) x 14 in (35 cm)12 in (30 cm) x 8.5 in (21 cm) x 14 in (35 cm)12 in (30 cm) x 6 in (15 cm) x 12 in (30 cm)Inquire
Treatment Pulse DurationsInquireExposure Duration: CW-Pulse: 10-3000 ms
Exposure Interval: CW-Pulse: 10-3000 ms
MicroPulse Duration: MicroPulse: 0.05-1.00 ms
MicroPulse Interval: MicroPulse: 1.00-10.00 ms
InquireInquireExposure Duration: CW-Pulse™: 10–3000 ms
Exposure Interval: CW-Pulse: 10–3000 ms
MicroPulse® Duration: MicroPulse: 0.05–1.00 ms
MicroPulse Interval: MicroPulse: 1.00–10.00 ms
MicroPulse Duty Cycle: Preset selections of 5%, 10%, and 15% (continuously adjustable from 0.4% - 50%)
Aim BeamDiode laser, 635 nm nominalDiode laser, 635 nm nominalDiode laser, 635 nm nominalDiode laser, 635 nm nominalDiode laser, 635 nm nominal