Ultrasonic Pachymeters (Ultrasound Pachymetry)

Ultrasound technology can help probe the human eye without causing damage to this delicate organ, and so its use in ophthalmology is constantly expanding. Ultrasonic pachymeters (or pachometers) allow the surgeon or general ophthalmologist to measure the thickness of the cornea in patients with glaucoma, suspected hypertension or those considering refractive surgery. One primary advantage of an ultrasonic pachymeter is how cost-effective it can be as compared to alternatives such as confocal microscopy. These pachymeters are generally hand-held. In addition to corneal thickness, the customer should seek capabilities like pre-programed formulas for intraocular lenses (IOL) and post-refractive surgery.
Showing 3 of 3 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.
Compare for selected.
MD-1000P Pachymeter

MD-1000P Pachymeter

MEDA CO., LTD.

  • Features: Multiple Corneal Maps with Graphical Display
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Biometry Accuracy: ≤±5µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
ODM-1000A/P Ultrasonic Biometer/Pachymeter
  • Features:
    • Automatic and manual gain control modes
    • Immersion Mode measurement
    • Live waveform display
    • Multi-modes measurements
    • Eight groups of measurements to calculate IOL.
    • Portable and sleek.
    • Stores up to 25 measurements by cornea location
    • Build-in thermal printer
      A-Biometer:
    • Gain ≥90dB
    • Gain changeable for users: 0-32dB
    • Accuracy: ≤0.06mm
    • Measure Range: 15-39mm
    • Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
    • Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
      Pachymeter:
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
  • Biometry Measurement: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
ODM-1000P Pachymeter

ODM-1000P Pachymeter

MEDA CO., LTD.

  • Features:
    • Stores up to 25 measurements by cornea location
    • Central and Peripheral cornea map
    • Build-in thermal printer
    • Accurate and Reliable
    • Portable and sleek
      Pachymeter
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Inquire
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.