Lacrimal Intubation and DCR (Dacryocystorhinostomy)

Showing 15 of 30 products
Get quotes for all products
Select up to 5 products from below to compare or request more information.

Featured products

Compare or Get quote for selected.
Bika-Bicanaliculus Intubation

Bika-Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: For Canalicular Stenosis. Non-traumatic tip. Silicone tubing swaged into probe. Note: Tubing securely swaged into malleable stainless steel probes. Medical grade silicone. Box of 3, sterile.
  • Product Number: S1-1000u
Read More
Compare or Get quote for selected.
Crawford Bicanaliculus Intubation

Crawford Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: Crawford bicanaliculus intubation available in silicone, stainless steel. For canalicular stenosis. Non traumatic rounded olive tip. It requires use of crawford hook. Box of 3. Sterile.
  • Product Number: S1-1270u
Read More
Compare or Get quote for selected.
Goldberg Bicanalicular Cerclage

Goldberg Bicanalicular Cerclage

FCI Ophthalmics Inc.

  • Description: For reconstruction, trauma and chronic stenosis of canalicular system. Medical grade silicone tubing (tapered at one end). Blue polypropylene suture. Box of 3, sterile.
  • Product Number: S1-1900u
Read More
Compare or Get quote for selected.
Infant Bika

Infant Bika

FCI Ophthalmics Inc.

  • Description: For Canalicular Stenosis in Infants. Medical grade silicone. Note: Can also be used in DCR because of its high flexibility. Probe entirely embedded in silicone tubing (non-traumatic). Box of 3, sterile.
  • Product Number: S1-1100u
Read More
Compare or Get quote for selected.
Med. Collarette MONOKA (3mm)

Med. Collarette MONOKA (3mm)

FCI Ophthalmics Inc.

  • Description: For canalicular laceration or imperforate nasolacrimal duct. Medical grade silicone and Stainless Steel Probe. Box of 3, sterile. Note: Tubing securely swaged into malleable stainless steel probes. System is anchored by punctum plug: no knots, no sutures, no interpalpebral loops.
  • Product Number: S1-1710u
Read More
Compare or Get quote for selected.
Mini MONOKA

Mini MONOKA

FCI Ophthalmics Inc.

  • Description: For canalicular laceration involving external 2/3 of one canaliculus. Medical grade silicone. Box of 3, sterile. Note: For safe and proper insertion of the punctum plug above, we recommend the use of disposable insertion devices # S1-3090u.
  • Product Number: S1-1500u
Read More
Compare or Get quote for selected.
Mono-Crawford Monocanalicular Intubation System
  • Description: A unique combination of the successful Monoka and the familiar Crawford lacrimal intubation systems. One end of the stent features a silicone plug that anchors the system securely in place at the punctum. The other end is the olive tipped probe that facilitates retrieval from the nose using the Crawford hook. Thanks to the anchoring plug, the single tube which is cut in the nose requires no knots or sutures. Stent removal is easy – simply grasp the plug below it’s collarette and pull out of the punctum. The use of the Mono-Crawford is appropriate for congenital naso-lacrimal duct obstruction, laceration, or in cases where only one punctum is functional. The Mono-Crawford stents come with either 3mm or 4mm collarettes.
  • Product Number: Medical Grade Silicone • Stainless Steel • Sterile

    S1-1901u • 3mm collarette • Box of 1
    S1-1911u • 4mm collarette • Box of 1
    S1-1903u • 3mm collarette • Box of 3
    S1-1913u • 4mm collarette • Box of 3

    PVP Mono-Crawford also available

    S1-1941u • 3mm collarette • Box of 1
    S1-1951u • 4mm collarette • Box of 1
    S1-1943u • 3mm collarette • Box of 3
    S1-1953u • 4mm collarette • Box of 3

Read More
Compare or Get quote for selected.
Ritleng Bicanaliculus Intubation

Ritleng Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the 300 mm 0.64 mm diam silicone tubing into place. Newly coated with a thin Polyvinylpyrrolidone (PVP) coating that makes the surface as slick as glass to enhance tear drainage and to prevent debris from collecting on the surface. For canalicular stenosis. Medical grade silicone. Blue Polypropylene thread-guide. It requires Ritleng Probe S1-1460u and Ritleng Hook S1-1480u. Box of 3, sterile.
  • Product Number: S1-1450u
Read More
Compare or Get quote for selected.
Ritleng Bicanaliculus Intubation

Ritleng Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the 300 mm 0.64 mm diam silicone tubing into place. Newly coated with a thin Polyvinylpyrrolidone (PVP) coating that makes the surface as slick as glass to enhance tear drainage and to prevent debris from collecting on the surface. For canalicular stenosis. Medical grade silicone. Blue Polypropylene thread-guide. It requires Ritleng Probe S1-1460u and Ritleng Hook S1-1480u. Box of 3, sterile.
  • Product Number: S1-1490u
Read More
Compare or Get quote for selected.
Ritleng Bicanaliculus Intubation

Ritleng Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the 300 mm 0.64 mm diam silicone tubing into place. Newly coated with a thin Polyvinylpyrrolidone (PVP) coating that makes the surface as slick as glass to enhance tear drainage and to prevent debris from collecting on the surface. For canalicular stenosis. Medical grade silicone. Blue Polypropylene thread-guide. It requires Ritleng Probe S1-1460u and Ritleng Hook S1-1480u.
  • Product Number: S1-1451u
Read More
Compare or Get quote for selected.
Ritleng Bicanaliculus Intubation

Ritleng Bicanaliculus Intubation

FCI Ophthalmics Inc.

  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the 300 mm 0.64 mm diam silicone tubing into place. Newly coated with a thin Polyvinylpyrrolidone (PVP) coating that makes the surface as slick as glass to enhance tear drainage and to prevent debris from collecting on the surface. For canalicular stenosis. Medical grade silicone. Blue Polypropylene thread-guide. It requires Ritleng Probe S1-1460u and Ritleng Hook S1-1480u. Box of 1, sterile.
  • Product Number: S1-1491u
Read More
Compare or Get quote for selected.
Self-Retaining Bicanaliculus Intubation Set
  • Description: Nicknamed the SRS, this new and innovative stent allows the physician to intubate the canaliculi in the office right at the chair with just topical anesthetic drops.

    The SRS is made of medical grade silicone and is available in three lengths 25mm, 30mm and 35mm (disposable sizers sold separately). At each end of the stent is an anchor-shaped head to provide fixation. Each head consists of two flexible winglets that fold inwards during insertion through the punctum and spread back out after passage through the junction of the common canaliculus and lacrimal sac, thus securing the stent in place. A centrally placed marking on the tube acts as a reference point and allows verification of proper stent positioning following insertion. The winglets fold backwards for easy removal of the stent from the ducts.

    Primary indications for the SRS include horizontal lacrimal duct stricture and punctal stenosis. Special consideration should be given to cancer patients on constricting drug therapies such as Taxotere®.

  • Product Number: Inquire
Read More
Compare or Get quote for selected.
Self-Threading MONOKA (Fayet-Bernard Ritleng Type, 3 mm COLLARETTE)
  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the silicone tubing in place. Canalicular Laceration or Imperforate Nasolacrimal Duct. Silicone, Blue Polyproylene Thread-Guide and 4mm COLLARETTE. Box of 1, Sterile.
  • Product Number: S1-1811u
Read More
Compare or Get quote for selected.
Self-Threading MONOKA (Fayet-Bernard Ritleng Type, 3 mm COLLARETTE)
  • Description: This unique system uses prolene as thread-guide reducing time and trauma in lacrimal duct intubation. The hollow Ritleng Probe is inserted into the nasolacrimal duct and a thin prolene thread-guide is fed through it. The probe is then withdrawn leaving the polypropylene thread to pull the silicone tubing in place. Canalicular Laceration or Imperforate Nasolacrimal Duct. Silicone, Blue Polyproylene Thread-Guide and 4mm COLLARETTE. Box of 3, Sterile.
  • Product Number: S1-1810u
Read More
Select up to 5 products from above to compare or request more information.
Showing 15 of 30 products

Tags:

Please Login or Register to Create Tags