Selective Laser Trabeculoplasty (SLT)

SLT or Selective Laser Trabeculoplasty is a procedure that uses a laser to aid in fluid drainage from the eye, decreasing pressure. This low-level laser opens the drainage angle of the eye so fluid can drain out of the front of the eye. A slit-lamp microscope is used to guide the laser into the trabecular meshwork of the eye. This procedure is often done as a primary treatment for open-angle glaucoma patients before other surgical procedures are tried.

SLT is a fairly low-risk surgical procedure and complications are rare. An SLT laser is often combined with a YAG laser. Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity. Having these lasers bundled together can benefit a practice in saving space and money as wells as improving practice efficiency.
Showing 3 of 3 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.
Compare for selected.
Lumenis Selecta II™ Portable, Clip-on, SLT Laser
  • Weight (lbs): 25 lbs (11 kg)
  • Energy: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 increments
  • Wavelength: 532 nm
  • Spot Size: 400 microns
  • Pulse Duration: 3ns (nanoseconds)
  • Repetition Rate: 3Hz
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Pulse Mode: Single Pulse
Read More
Inquire
Compare for selected.
Selecta Duet™ SLT and YAG Photodisruptor
  • Weight (lbs): <60 kg>
  • Energy: YAG: 0.3mJ - 10mJ per pulse
    SLT: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 increments
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
  • Pulse Duration: 3ns (nanoseconds)
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Pulse Mode: YAG: 1, 2 or 3 pulses per burst (selectable)
    SLT: Single pulse
Read More
Inquire
Compare for selected.
Selecta Trio™ YAG Laser, SLT and Photocoagulation
  • Weight (lbs): Inquire
  • Energy: YAG: 0.3ml - 10ml per pulse
    SLT: 0.3 - 2ml per pulse, continously variable in 0.1 increments
    PC: 50 - 2500mW
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
    PC: 532 nm
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
    PC: 50 - 100 on Z-Link; 5-500 on Convrg-Link
  • Pulse Duration: YAG: 3 ns
    SLT: 3 ns
    PC: 0.01-3 seconds
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
    PC: N/A
  • Power Requirements: Inquire
  • Cooling: YAG & SLT: Air cooled
    PC: Air cooled, enhanced with TEC
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.