SLT or Selective Laser Trabeculoplasty is a procedure that uses a laser to aid in fluid drainage from the eye, decreasing pressure. This low-level laser opens the drainage angle of the eye so fluid can drain out of the front of the eye. A slit-lamp microscope is used to guide the laser into the trabecular meshwork of the eye. This procedure is often done as a primary treatment for open-angle glaucoma patients before other surgical procedures are tried.
SLT is a fairly low-risk surgical procedure and complications are rare. An SLT laser is often combined with a YAG laser. Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity. Having these lasers bundled together can benefit a practice in saving space and money as wells as improving practice efficiency.
Select up to 5 products from below to compare or request more information.
- Weight (lbs): 68 lbs (31 kg) (laser only)
- Energy: SLT mode: 0.3 to 2.6 mJ per pulse, continuously variable
YAG mode: 0.3 to 10 mJ per pulse, continuously variable - Wavelength:
- SLT mode: green 532 nm
- YAG mode: infrared 1064 nm
- Spot Size: SLT mode: 400 µm
YAG mode: 8 µm - Pulse Duration: Inquire
- Repetition Rate: up to 4 Hertz
- Power Requirements: 100–240 VAC, 50/60 Hz, 800 VA
- Cooling: Air cooled
- Laser Source: SLT mode: Q-switched, frequency doubled Nd:YAG
YAG mode: Q-switched Nd:YAG - Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
- Aiming Beam: SLT mode: red 635 nm, adjustable intensity
YAG mode: green 515 nm, adjustable intensity - Pulse Mode: Inquire
Read More
Inquire
- Weight (lbs): 68 lbs (31 kg) (laser only)
- Energy: SLT Mode: 0.3 to 2.6 mJ, per pulse, continuously variable
YAG Mode: 0.3 to 10 mJ, per pulse, continuously variable - Wavelength: SLT Mode: green: 532 nm
YAG Mode: 1064 nm - Spot Size: SLT Mode: 400 µm
YAG Mode: 8 µm - Pulse Duration: SLT Mode: 3 ns
YAG Mode: 4 ns - Repetition Rate: up to 3 hertz
- Power Requirements: 100-240 VAC, 50/60 Hz, 800 VA
- Cooling: air cooled
- Laser Source: Inquire
- Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
- Aiming Beam: red 635 nm, adjustable intensity
- Pulse Mode: Inquire
Read More
Inquire
- Weight (lbs): 30 kg, 66 lbs (laser only)
- Energy: 0.3 to 2.6 mJ, single pulse, continuously variable
- Wavelength: Green 532nm
- Spot Size: 400µm
- Pulse Duration: Inquire
- Repetition Rate: up to 3Hz
- Power Requirements: Inquire
- Cooling: Air cooled
- Laser Source: Q-switched, frequency doubled Nd:YAG
- Dimensions (W × H × D): 57x75x44 cm, 23x30x18 in (laser only)
- Aiming Beam: Red 635 nm, adjustable intensity
- Pulse Mode: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.