Selective Laser Trabeculoplasty (SLT)

SLT or Selective Laser Trabeculoplasty is a procedure that uses a laser to aid in fluid drainage from the eye, decreasing pressure. This low-level laser opens the drainage angle of the eye so fluid can drain out of the front of the eye. A slit-lamp microscope is used to guide the laser into the trabecular meshwork of the eye. This procedure is often done as a primary treatment for open-angle glaucoma patients before other surgical procedures are tried.

SLT is a fairly low-risk surgical procedure and complications are rare. An SLT laser is often combined with a YAG laser. Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity. Having these lasers bundled together can benefit a practice in saving space and money as wells as improving practice efficiency.
Showing 9 of 9 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.

Featured products

Compare for selected.
Tango Reflex™ SLT/YAG Multi-Modality Laser
  • Weight (lbs): 68 lbs (31 kg) (laser only)
  • Energy: SLT mode: 0.3 to 2.6 mJ per pulse, continuously variable
    YAG mode: 0.3 to 10 mJ per pulse, continuously variable
  • Wavelength:
    • SLT mode: green 532 nm

    • YAG mode: infrared 1064 nm
  • Spot Size: SLT mode: 400 µm
    YAG mode: 8 µm
  • Pulse Duration: Inquire
  • Repetition Rate: up to 4 Hertz
  • Power Requirements: 100–240 VAC, 50/60 Hz, 800 VA
  • Cooling: Air cooled
  • Laser Source: SLT mode: Q-switched, frequency doubled Nd:YAG
    YAG mode: Q-switched Nd:YAG
  • Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
  • Aiming Beam: SLT mode: red 635 nm, adjustable intensity
    YAG mode: green 515 nm, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Tango: SLT/YAG Combination Laser System
  • Weight (lbs): 68 lbs (31 kg) (laser only)
  • Energy: SLT Mode: 0.3 to 2.6 mJ, per pulse, continuously variable
    YAG Mode: 0.3 to 10 mJ, per pulse, continuously variable
  • Wavelength: SLT Mode: green: 532 nm
    YAG Mode: 1064 nm
  • Spot Size: SLT Mode: 400 µm
    YAG Mode: 8 µm
  • Pulse Duration: SLT Mode: 3 ns
    YAG Mode: 4 ns
  • Repetition Rate: up to 3 hertz
  • Power Requirements: 100-240 VAC, 50/60 Hz, 800 VA
  • Cooling: air cooled
  • Laser Source: Inquire
  • Dimensions (W × H × D): 75 cm (30 in) x 57 cm (23 in) x 44 cm (18 in) (laser only)
  • Aiming Beam: red 635 nm, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Lumenis Selecta II™ Portable, Clip-on, SLT Laser
  • Weight (lbs): 25 lbs (11 kg)
  • Energy: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 increments
  • Wavelength: 532 nm
  • Spot Size: 400 microns
  • Pulse Duration: 3ns (nanoseconds)
  • Repetition Rate: 3Hz
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Pulse Mode: Single Pulse
Read More
Inquire
Compare for selected.
Selecta Duet™ SLT and YAG Photodisruptor
  • Weight (lbs): <60 kg>
  • Energy: YAG: 0.3mJ - 10mJ per pulse
    SLT: 0.3 - 2.0mJ per pulse, continuously variable in 0.1 increments
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
  • Pulse Duration: 3ns (nanoseconds)
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Pulse Mode: YAG: 1, 2 or 3 pulses per burst (selectable)
    SLT: Single pulse
Read More
Inquire
Compare for selected.
Selecta Trio™ YAG Laser, SLT and Photocoagulation
  • Weight (lbs): Inquire
  • Energy: YAG: 0.3ml - 10ml per pulse
    SLT: 0.3 - 2ml per pulse, continously variable in 0.1 increments
    PC: 50 - 2500mW
  • Wavelength: YAG: 1064 nm
    SLT: 532 nm
    PC: 532 nm
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
    PC: 50 - 100 on Z-Link; 5-500 on Convrg-Link
  • Pulse Duration: YAG: 3 ns
    SLT: 3 ns
    PC: 0.01-3 seconds
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
    PC: N/A
  • Power Requirements: Inquire
  • Cooling: YAG & SLT: Air cooled
    PC: Air cooled, enhanced with TEC
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Volk SLT Lens

Volk SLT Lens

Volk Optical, Inc.

  • Weight (lbs): Inquire
  • Energy: Inquire
  • Wavelength: Inquire
  • Spot Size: 1.0x
  • Pulse Duration: Inquire
  • Repetition Rate: Inquire
  • Power Requirements: Inquire
  • Cooling: Inquire
  • Laser Source: Inquire
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Inquire
  • Pulse Mode: Inquire
Read More
Inquire
Compare for selected.
Solo™ SLT

Solo™ SLT

Ellex

  • Weight (lbs): 30 kg, 66 lbs (laser only)
  • Energy: 0.3 to 2.6 mJ, single pulse, continuously variable
  • Wavelength: Green 532nm
  • Spot Size: 400µm
  • Pulse Duration: Inquire
  • Repetition Rate: up to 3Hz
  • Power Requirements: Inquire
  • Cooling: Air cooled
  • Laser Source: Q-switched, frequency doubled Nd:YAG
  • Dimensions (W × H × D): 57x75x44 cm, 23x30x18 in (laser only)
  • Aiming Beam: Red 635 nm, adjustable intensity
  • Pulse Mode: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.