for selected.
IOLMaster 500® Optical Biometry
Carl Zeiss Meditec, Inc.
Features
: Launched in 2000, the IOLMaster was the first automatic biometry system available which did not make contact with the patient’s eye. There are now more than 11,000 units in the world today, making the IOLMaster the Gold Standard for cataract biometry. The new IOLMaster 500 features several advanced new capabilities, including:
Increased Speed: In individual practice studies, the new IOLMaster 500 has been shown to complete all measurements in as few as 80 seconds*.
Dual-mode Measurements: Axial length and keratometry calculations can be collected simultaneously, at the push of a button.
Composite Signal Filtering: New sound filtering technology excludes poor readings and increases the percentage of cataract patients that can be measured.
Seamless Data Integration with the Synergy Ultrasound A-scan: This time-saving feature allows easy workflow integration of A-scan ultrasound biometry for difficult cases, such as extremely dense cataracts.
Easy Data Transfer to the Holladay Consultant Program: The Holladay II formula has become very popular among physicians in North America.
New Graphical User Interface: With green, red and yellow “traffic light” reporting, technicians of all experience levels can achieve highly accurate diagnostic results.
* Based on single-practice study conducted by Oliver Findl, MD, Vienna Institute for Research in Ocular Surgery, Vienna, Austria.
Read More
Get quote
Compare
or
Get quote
for selected.
LENSTAR LS 900 Optical Biometer
Haag-Streit USA, Inc.
Related
Related Featured Article
Related Videos
Features
:
LENSTAR is the first optical biometer which uses the precision of OLCR
(Optical Low-Coherence Reflectometry) for all its measurements, including ACD and lens thickness. OLCR is an advanced technology, similar to Time Domain OCT.
As a biometer of the entire eye, one LENSTAR® scan
consists of 16 individual full eye scans and 4 individual keratometric scans, taken on 2 concentric rings, along the patient's visual axis.
LENSTAR's software runs on an external PC.
This minimizes costly upgrades, software crashes and hardware repairs, and allows direct communication with EMR and networks as well as auto-population of data fields from third party IOL calculators such as Holladay II, eliminating the risk and liability potential of transcription error.
All of the standard IOL prediction formulas (Holladay I, SRK-T, Haigis and Hoffer Q) are built into the software
– with potential for future formulas to be added. Since LENSTAR measures more parameters than current formulas allow, the system is ready to incorporate future generations of power calculations as they are developed.
LENSTAR uses a proprietary intelligent detection system.
The patient fixates on the measurement beam. This ensures all measurements are on the patient's visual axis. If the patient blinks or loses fixation, LENSTAR detects this and resumes again when the patient's fixation returns.
1 SCAN - 9 MEASUREMENTS - 30 SECONDS
Read More
Get quote
Compare
or
Get quote
for selected.
ODM-1000A Ultrasonic Biometer
MEDA CO., LTD.
Features
:
Auto/Manual gain selectable.
Immersion/Contact Measuring mode
8 waveform readings for average.
Multi modes for different eyes.
IOL results printable with waveforms.
Save up to 34 groups of results.
Portable and convenient for out-call.
Specifications:
Gain ≥ 90dB
Gain changeable for users: 0-32dB
Accuracy: ≤0.06mm
Measure Range:15-39mm
Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, and Haigis
Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudo-aphakic, Manual
Read More
Get quote
View Company Product Page
Compare
or
Get quote
for selected.
ODM-1000A/P Ultrasonic Biometer/Pachymeter
MEDA CO., LTD.
Related
Related New Product
Features
:
Automatic and manual gain control modes
Immersion Mode measurement
Live waveform display
Multi-modes measurements
Eight groups of measurements to calculate IOL.
Portable and sleek.
Stores up to 25 measurements by cornea location
Build-in thermal printer
A-Biometer:
Gain ≥90dB
Gain changeable for users: 0-32dB
Accuracy: ≤0.06mm
Measure Range: 15-39mm
Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
Pachymeter:
Frequency: 20MHz
Biometry Accuracy: 5 µm
Display Resolution: 1µm
Measure scope: 200-1100µm
Read More
Get quote
View Company Product Page
Select All
Select up to 5 products from above to compare or request more information.
Get quotes
Compare
Tags:
Please Login or Register to Create Tags
Feedback
Articles
AAO 2011 Exhibit Hall Highlights
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
advertisement
Related Articles
ASCRS Cornea Day 2012
Friday, April 20, 2012
ASCRS/ASOA Congress on Ophthalmic Practice ...
Friday, April 20, 2012
ASCRS Symposium on Cataract, IOL and Refractive ...
Friday, April 20, 2012
APAO/SOE Busan 2012
Friday, April 13, 2012
Pearls for the Preoperative Evaluation and ...
Wednesday, February 08, 2012