BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .60mm x 23.5mm (23 G x 15/16 in), .40mm top port, thinwall Cannula
  • Gauge: .60mm (23 G)
  • Tip: Angled, Micro-etched 2.0mm from end
  • Product Description: .40mm top port, thinwall Cannula angled 30°, 2mm from end, Micro-etched 2mm from end. May also be useful for capsule polishing
Read More
Inquire
Compare for selected.
BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .60mm x 16.0mm (23 G x 5/8 in)
  • Gauge: .60mm (23 G)
  • Tip: .60 x 16mm, .30mm top port
  • Product Description: Curved shape Cannula .30mm top port
Read More
Inquire
Compare for selected.
BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .55 mm x 22 mm
  • Gauge: 24
  • Tip: .55 x 22 mm (24G x 7/8 in); .30 mm open end port, hook 2.75 mm long x 2.5 mm wide. Slightly micro etched on back of J shape end for capsule polishing. May also be used for aspiration of cortex from the suerior iris between the 10 - 2 o'clock meridian.
  • Product Description: Slightly micro etched on back of J shape end for capsule polishing. May also be used for aspiration of cortex from the suerior iris between the 10 - 2 o'clock meridian.
Read More
Inquire
Compare for selected.
BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .80mm x 16.0mm (21 G x 5/8 in)
  • Gauge: .80mm (21 G)
  • Tip: .80 x 16mm, (21G x 5/8 in);30mm top port
  • Product Description: Curved shape Cannula .30mm top port
Read More
Inquire
Compare for selected.
BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .55mm (24 G)
  • Gauge: .55mm (24 G)
  • Tip: .30mm end port Angled 10°
  • Product Description: .30mm top port angled 10°, flat end opening has rounded edges
Read More
Inquire
Compare for selected.
BD Visitec™ Cortex Extractor

BD Visitec™ Cortex Extractor

Beaver-Visitec International

  • Dimension: .60mm x 16.0mm (23 G x 5/8 in)
  • Gauge: .60mm (23 G)
  • Tip: Curved
  • Product Description: Curved with .40mm top port
Read More
Inquire
Compare for selected.
BD Visitec™ J Shape Cannula

BD Visitec™ J Shape Cannula

Beaver-Visitec International

  • Dimension: .60mm x 22.0mm (23 G x 7/8 in)
  • Gauge: .60mm (23 G)
  • Tip: Hook is 2.0mm long x 2.25 mm wide
  • Product Description: J shape .25mm open-end port, Useful for retracting iris & aspirating difficult to reach cortex between the 10-2 o'clock meridian.
Read More
Inquire
Compare for selected.
BD Visitec™ J Shape Cannulas

BD Visitec™ J Shape Cannulas

Beaver-Visitec International

  • Dimension: .50 x 20.0mm (25 G x 3/4 in)
  • Gauge: .50mm (25 G)
  • Tip: Hook is .85mm long x 1.7mm wide
  • Product Description: J shape .25mm open-end port, Useful for retracting iris & aspirating difficult to reach cortex between the 10-2 o'clock meridian
Read More
Inquire
Compare for selected.
BD Visitec™ Micro J Shape Cannula

BD Visitec™ Micro J Shape Cannula

Beaver-Visitec International

  • Dimension: .50 x 22.0mm (25 G x 7/8 in)
  • Gauge: .50mm (25 G)
  • Tip: 1.5mm long x 1.75mm wide hook
  • Product Description: Designed for small incision surgery, J Shape .25mm open-end port, Useful for retracting iris & aspirating difficult to reach cortex between the 10-2 o'clock meridian
Read More
Inquire
Compare for selected.
Bimanual Aspiration Cannula

Bimanual Aspiration Cannula

Hurricane Medical

  • Dimension: 23G x 7/8in (/60 x 22mm)
  • Gauge: 23
  • Tip: Micro etched 2mm from end for capsule polishing
  • Product Description: For removing cortical debris and / or viscoelastic substances. Insert through two side port incisions or side port and phacoemulsification incisions.
Read More
Inquire
Compare for selected.
Bimanual Irrigation Cannula

Bimanual Irrigation Cannula

Hurricane Medical

  • Dimension: 21G x 7/8in (.80 x 22mm)
  • Gauge: 21
  • Tip: Inquire
  • Product Description: For removing cortical debris and / or viscoelastic substances. Insert through two side port incisions or side port and phacoemulsification incisions.
Read More
Inquire
Compare for selected.
Cortex Extractor

Cortex Extractor

Hurricane Medical

  • Dimension: 23G x 7/8in (/60 x 22mm)
  • Gauge: 23
  • Tip: Inquire
  • Product Description: For removing cortical debris and / or viscoelastic substances. For aspirating when chamber is maintained with a viscoelastic, anterior chamber maintainer or other independent source.
Read More
Inquire
Compare for selected.
Cortex Extractor

Cortex Extractor

Hurricane Medical

  • Dimension: 21G x 7/8in (.80 x 22mm)
  • Gauge: 21
  • Tip: Inquire
  • Product Description: For removing cortical debris and / or viscoelastic substances. For aspirating when chamber is maintained with a viscoelastic, anterior chamber maintainer or other independent source.
Read More
Inquire
Compare for selected.
Cortex Extractor - Charleux

Cortex Extractor - Charleux

Hurricane Medical

  • Dimension: 23G x 7/8in (/60 x 22mm)
  • Gauge: 23
  • Tip: Inquire
  • Product Description: For removing cortical debris and / or viscoelastic substances. For aspirating when chamber is maintained with a viscoelastic, anterior chamber maintainer or other independent source.
Read More
Inquire
Compare for selected.
I and A Cannula - Simcoe

I and A Cannula - Simcoe

Hurricane Medical

  • Dimension: 23G / 23G (.60/.60mm)
  • Gauge: 23
  • Tip: Inquire
  • Product Description: For removing cortical debris and / or viscoelastic substances. Irrigation is provided through cannula with open end port. Asipiration is provided through 10 inch (25cm) flexible tubing attached to cannula.
Read More