YAG Lasers for Trabeculotomy and Capsulotomy

YAG lasers are often used for Capsulotomy and Trabeculectomy procedures. Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity whereas Trabeculectomy is a procedure used in Glaucoma patients to relieve intraocular pressure via YAG laser. A Capsulotomy is necessary when the capsule becomes cloudy because of healing scar tissue. This is a fairly common condition post-operatively. The Yag Laser creates a tiny hole in the posterior membrane to allow the passage of light through and to restore clear and unobstructed vision. A Trabeculectomy or SLT (Selective Laser Trabeculectomy) is partial removal of the trabecular meshwork and surrounding areas to drain excess fluid and relieve pressure.

Many YAG lasers on the market now boast the dual features that enable an Ophthalmologist to perform both Capsulotomy and Trabeculectomy procedure via one laser. This allows an Ophthalmology practice to utilize available space and decrease the amount of large equipment needed. Many of these YAG lasers offer upgradable features that are available to add on at a later date, insuring your practice stays up to date.
Showing 4 of 4 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.
Compare for selected.
Aura PT™ Ophthalmic YAG Photodisruptor Laser
  • Features:
    • Two defocus positions that can easily be changed with a roll of your finger
    • Sophisticated focusing system ensures superior accuracy in energy placement
    • Advanced precision optics offer maximum visibility for more precise diagnosis and treatment
    • Compact and lightweight design optimizes the physician's working space
  • Mode: Fundamental Q-Switched
  • Weight (lbs): System: 46.3 lbs (21 kg)
  • Magnification: 5 Steps: 6x, 10x, 16x, 25x, 40x
  • Slit lamp: CSO SL 950
  • Spot Size: 8 µm
  • Cooling System: Air convection
  • Pulse Length/Width: 4 nanseconds (typical)
  • Repetition Rate: 2.5 Hz
  • Electrical Requirements: 100V - 240V AC, 50/60 Hz
  • Dimensions (W × H × D): 12.5 in (32 cm) x 20.5 in (52 cm) x 17.7 in (45 cm)
  • Aiming Beam: Dual beam 635 nm diode continously variable intensity to 200 µm
  • Treatment Laser Type: Nd:YAG
  • Laser Wavelength: 1064 nm
  • Laser Energy: Continously adjustable from 0.2 to 10 mJ
  • Exit Aperture Angle: Inquire
  • Burst Mode: 1, 2, 3 pulses each burst; separation between pulses is 20 µs
  • Cone Angle: 16 degrees
  • Offset Focus: Continously variable from anterior (-)500 µm to posterior (=)500 µm; detent steps @ 0, 150, 250, 500 µm
Read More
Inquire
Compare for selected.
Lumenis Selecta II™ Portable, Clip-on, SLT Laser
  • Features:
    • True Portability
    • Maximum Space Utilization
    • Compatible with most commercially available converging-optics style slit lamps
  • Mode: Inquire
  • Weight (lbs): 25 lbs (11 kg)
  • Magnification: Inquire
  • Slit lamp: Compatible with most commercially available converging-optics style slit lamps
  • Spot Size: 400 microns
  • Cooling System: Air cooled
  • Pulse Length/Width: Inquire
  • Repetition Rate: 3Hz
  • Electrical Requirements: 100 -240 VAC, 50/60 Hz, 3.15 Amps
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Treatment Laser Type: Inquire
  • Laser Wavelength: Inquire
  • Laser Energy: Inquire
  • Exit Aperture Angle: Inquire
  • Burst Mode: Inquire
  • Cone Angle: Inquire
  • Offset Focus: Inquire
Read More
Inquire
Compare for selected.
Selecta Duet™ SLT and YAG Photodisruptor
  • Features:
    • Proprietary advanced laser design, with automatic internal tests to ensure power requirements and a secondary control unit to guarantee power accuracy.
    • Highly-accurate Super Gaussian beam profile in YAG mode
    • Table is equipped with built-in compact storage space for lenses or other accessories
    • Ergonomically designed joystick includes a convenient integrated laser fire-switch.
    • Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
    • Slit lamp function includes a 6-step magnification changer.
    • Table height can be easily adjusted using its electronic up/down switch
  • Mode: Inquire
  • Weight (lbs): <60 kg>
  • Magnification: Inquire
  • Slit lamp: Inquire
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
  • Cooling System: Air cooled
  • Pulse Length/Width: Inquire
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
  • Electrical Requirements: 100 -240 VAC, 50/60 Hz, 3.15 Amps
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable adjustable intensity
  • Treatment Laser Type: Inquire
  • Laser Wavelength: Inquire
  • Laser Energy: Inquire
  • Exit Aperture Angle: Inquire
  • Burst Mode: Inquire
  • Cone Angle: Inquire
  • Offset Focus: Inquire
Read More
Inquire
Compare for selected.
Selecta Trio™ YAG Laser, SLT and Photocoagulation
  • Features:
    • Homogeneous Laser Beam in Photo-Coagulator mode
    • Dual Fiber Port -- Instantly switch between delivery devices
    • ClearView™ Filters -- Optimized view of treatment site
    • AcuGuide™ Micromanipulator for accurate and safe laser beam guidance for fine-tuned laser application on target tissue.
    • Integrated LaserLink Cradle safely and conveniently stow
    • Table is equipped with built-in compact storage space for lenses or other accessories
    • The ergonomically designed joystick includes a convenient integrated laser fire-switch.
    • Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
    • Slit lamp function includes a 6-step magnification changer.
    • Table height can be easily adjusted using its electronic up/down switch.
  • Mode: Inquire
  • Weight (lbs): Inquire
  • Magnification: Inquire
  • Slit lamp: Inquire
  • Spot Size: YAG: 8 microns
    SLT: 400 microns
    PC: 50 - 100 on Z-Link; 5-500 on Convrg-Link
  • Cooling System: Inquire
  • Pulse Length/Width: Inquire
  • Repetition Rate: YAG: 3Hz (in single burst)
    SLT: 3Hz
    PC: N/A
  • Electrical Requirements: 100-240 VAC, 50/60 Hz, 3.15 Amps
  • Dimensions (W × H × D): Inquire
  • Aiming Beam: Red Diode, continuously variable, adjustable intensity
  • Treatment Laser Type: Inquire
  • Laser Wavelength: Inquire
  • Laser Energy: Inquire
  • Exit Aperture Angle: Inquire
  • Burst Mode: Inquire
  • Cone Angle: Inquire
  • Offset Focus: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.