Octopus 900 Perimeter from Haag-Streit USA, Inc.

  • Octopus 900 Perimeter

Description

Addressing all major perimetry needs, the Octopus 900 from Haag-Streit is the perimeter of choice for anyone who wants diagnostic flexibility to analyse, assess and track patients’ visual fields. Everything you can ask of a perimeter is offered in one device -- full field static and kinetic perimetry, an easy-to-read analysis software, and the ability to network it with integrated EyeSuite software.
  • Product Specs
  • ItemOctopus 900 Perimeter
  • CompanyHaag-Streit USA, Inc.
  • PriceGet quote
  • Features
    • Six Methods – One Perimeter
    • 100% Fixation Control – 100% of the Time.
    • Lightning-fast full threshold exams in fewer than 150 seconds
    • EyeSuite™ Software Analysis with networkable system and EMR Integration.
    • Goldmann Kinetic Perimetry in both manual and semi-automated modalities utilizing our full 90 Degree standard Goldmann bowl
    • Improved Patient Comfort and Greater Flexibility
    • Import existing HFA data (700 series)
    • HFA Style printout
    • Three forms of glaucoma progression analysis - including structure/function
  • Analysis SoftwareEyeSuite™ Software Analysis with networkable system and EMR Integration.
  • Weight (lbs)55 lbs (25 kg)
  • StimulusMirror projection system
  • Fixation ControlBlink Control, Pupil Position Control, AET (Automated Eye Tracking)
  • Test StrategiesTOP (Tendency Oriented Perimetry, 2–4 min)
    Dynamic (adaptive step size, 6–8 min)
    Normal (4-2-1 bracketing, 10–12 min)
    Other (LV: Low Vision with Goldmann size V; 2-LT: 2-Level Test, 1-LT: 1-Level Test; GST: Glaucoma Screening Test)
  • Test Method
    • Standard white-on-white perimetry SAP
    • Blue/yellow perimetry SWAP
    • Flicker perimetry for early diagnosis
    • Red/white perimetry (custom tests only)
    • Goldmann Kinetic Perimetry
  • Dimensions (W × H × D)648 mm (25.5 in) x 796 mm (31.3 in) x 519 mm (20.4 in)
  • Peripheral Range180° (30 cm radius Goldmann bowl)
  • Stimulus Size(Goldmann) I, II, III, IV, V
  • Stimulus Duration100, 200, 500, 1000, infinite
  • Background Illumination0/4/31/314
  • Networking Capabilities DICOM, EMR, Ethernet
  • Data StorageOctopus 101, 123, 300 and 600; HFA
  • Test Pattern
    • General/Glaucoma 30° (G1-Program, 32, 30-2, 24-2)
    • General/Glaucoma Periphery (G2-Program: 60°; 07-Program: 75°)
    • Macula (M-Program (10°/30°); 10-2)
    • Screening (ST)
    • Driving (Estermann monocular/binocular; FG: German Driving Licence)
    • Disability (BT – Blepharoptosis; BG: German Blindness)
    • Other Pathology (N1: Neurological; D1: Diabetes)
    • Custom tests