PASCAL Streamline™ Photocoagulator from Topcon Medical Laser Systems

  • PASCAL Streamline™ Photocoagulator

Description

PASCAL Streamline™ Photocoagulator combines core PASCAL® technology with enhanced patterns and powerful reporting. Designed from treating over 500,000 patients and delivering 25 million patterns, Streamline continues the PASCAL legacy of improving the photocoagulation experience for patients, physicians and practices.
  • Product Specs
  • ItemPASCAL Streamline™ Photocoagulator
  • CompanyTopcon Medical Laser Systems
  • PriceGet quote
  • FeaturesPrecision and Control from PASCAL Technology

    PASCAL's unique method controls laser delivery in four ways, enabling greater precision and control at the tissue level:

    • Short pulse duration
      • less heat diffusion to the retina and choroid
      • targeted burns with less collateral damage to surrounding tissue
    • Continuous laser pulse directed by three high speed galvanometers
      • uniform, predictable pulses
    • Precise pattern spacing
      • consistently spaced burns, minimizing overlap
    • Safety checks of galvo position and power
      • 100,000 times per second

      Power and Simplicity of Enhanced Patterns

      PASCAL Streamline's 2R/G software provides easy access to tens of thousands of patterns.

      • With the touch of a finger, create arrays, lines and rectangles
      • With one foot pedal depression, encircle a tear with a triple ring
      • Without taking your eyes off the oculars, deliver sequential patterns

      Robust and Tailored Reporting

      Unique PASCAL data can be coupled with patient information to:

      • Automatically generate a detailed printed summary of each Streamline procedure
      • Confirm patient identity prior to treatment and document that safety checks are performed
      • Search treatment history and produce detailed usage reports to ensure that every procedure is captured for billing

      Versatility of Streamline Modules

      • Video teaching system with integrated video camera and monitor
      • Patterned Laser Trabeculoplasty (PLT) module.
  • LaserOptically Pumped Semiconductor Laser (OPSL)
  • Wavelength532 nm
  • PatternsSingle spot, Square, Macular Grid, Octants, Arcs, Triple Arcs
  • Power0 - 2000 mW
  • Pulse Duration10 - 1000 ms
  • Delivered Spot SizeDelivered Spot Size: 60, 100, 200 or 400 µm diameter at the corneal plane
    Retinal Spot Size: Determined by the product of the spot size and the contact lens laser magnification factor
  • User InterfaceTouch screen control panel display 10.4"
    Mounted on slit lamp table, able to rotate 180 degrees
  • Slit LampCustom slit lamp design with Leica optics
    Slit Lamp Table: Ergonomically designed
  • CoolingTEC / Air cooled